2010
DOI: 10.1590/s2179-83972010000300011
|View full text |Cite
|
Sign up to set email alerts
|

Comparação entre um cateter único dedicado e cateteres de Judkins na realização da cineangiocoronariografia pela via radial direita

Abstract: RESUMOIntrodução: O espasmo radial é considerado um dos principais fatores de insucesso na via radial. O tempo prolongado de exame, a utilização de cateteres de maior diâme-tro, as fricções do cateter durante a manipulação e o número de cateteres utilizados estão entre as principais causas. A utilização de cateteres únicos dedicados a esse acesso poderia minimizar tais fatores, com consequente diminuição da incidência de espasmo. Método: Registro prospectivo de pacientes consecutivos com suspeita de doença cor… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
0
2
1

Year Published

2011
2011
2016
2016

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 19 publications
0
0
2
1
Order By: Relevance
“…We observed a crossover rate of 15%, which is higher compared to the 6.5% reported by Tebet et al [ 12 ], but lower than the 44% crossover rate reported by Langer et al [ 13 ]. In the study by Tebet et al, the success rate and procedural duration were similar for the overall population, with an advantage for the TIG catheter.…”
Section: Discussioncontrasting
confidence: 80%
“…We observed a crossover rate of 15%, which is higher compared to the 6.5% reported by Tebet et al [ 12 ], but lower than the 44% crossover rate reported by Langer et al [ 13 ]. In the study by Tebet et al, the success rate and procedural duration were similar for the overall population, with an advantage for the TIG catheter.…”
Section: Discussioncontrasting
confidence: 80%
“…In addition, they demonstrated that based on the two‐catheter‐concept, Judkins catheters—irrespective of which tube size—were generally associated with more periprocedural contrast and radiation exposure. In our study, we observed a crossover rate of 10.8%, which is higher compared to 6.5% and 9% crossover rate reported by Tebet and Kim et al, respectively; however, is lower than the 15% and 44% crossover rate reported by Vorpahl and Langer et al, respectively.…”
Section: Discussioncontrasting
confidence: 76%
“…Embora a maioria dos procedimentos tenha sido realizada com cateteres pré-moldados de Judkins, a utilização de apenas um cateter pode ser benéfica. Tebet et al 22 demonstraram que o cateter diagnóstico dedicado à técnica radial (Optitorque TM TIG, Terumo Corporation, Tóquio, Japão) permite exames com menor tempo total e menor tempo de fluoroscopia. Esse fato demonstra que, além da curva de aprendizado, a utilização de materiais específicos para a via radial é fundamental para a otimização dos resultados.…”
Section: Discussionunclassified