Micro-leakage at the implant-abutment interface with different tightening torques in vitro

Abstract: ObjectivesThis study evaluated the microleakage at the implant/abutment interface of external hexagon (EH) implants and abutments with different amounts of bacteria and tightening torques. Material and MethodsA bacterial suspension was prepared to inoculate the implants. The first phase of this study used nine EH implants and abutments that were divided into three groups with different amounts of bacterial suspension (n=3): V0.5: 0.5 µL; V1.0: 1.0 µL e V1.5: 1.5 µL, and tightened to the manufacturer's recommen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

4
27
0
4

Year Published

2014
2014
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 29 publications
(35 citation statements)
references
References 21 publications
4
27
0
4
Order By: Relevance
“…These volumes may also lead to low levels of bacterial suspension in relation to the I-A interface, hindering the microleakage 15 and showing negative results for microleakage as in previous studies 7,16 . These results reinforce the theory that high concentrations of bacteria and reduced volumes may mask the microleakage [14][15] . Moreover, it may lead to false negative results caused by bacterial death inside the implants.…”
Section: Discussionsupporting
confidence: 88%
See 4 more Smart Citations
“…These volumes may also lead to low levels of bacterial suspension in relation to the I-A interface, hindering the microleakage 15 and showing negative results for microleakage as in previous studies 7,16 . These results reinforce the theory that high concentrations of bacteria and reduced volumes may mask the microleakage [14][15] . Moreover, it may lead to false negative results caused by bacterial death inside the implants.…”
Section: Discussionsupporting
confidence: 88%
“…In order to avoid this, beyond the precautions on the concentration of bacterial suspension, bacterial viability was confirmed after the follow up period by disassembling the specimens that presented negative results for microleakage. Precaution involving the concentration of bacterial suspensions is already a reality; 4,5,14 but confirmation of bacterial viability was made only in two studies 5,14 . The chosen post-inoculation control test was immersion of the implants up to the I-A interface coating for 30 s. The overflow control by immersion was used in a previous study and showed good results 9 .…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations