2008
DOI: 10.1590/s1677-54492008000200004
|View full text |Cite
|
Sign up to set email alerts
|

Confiabilidade de testes de caminhada em pacientes claudicantes: estudo piloto

Abstract: CONTEXTO: Uma vez que a obstrução arterial periférica pode se apresentar de maneira difusa, com clínica diversa e com resultados de intervenção variados, é fundamental que a avaliação dos pacientes com doença arterial obstrutiva periférica seja feita com instrumentos que possam apresentar dados objetivos e reprodutíveis. OBJETIVO: Investigar e contrastar a confiabilidade do teste de caminhada de 6 minutos (T6M) com teste de deslocamento bidirecional progressivo (TDBP) em indivíduos claudicantes portadores de d… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
4
0
3

Year Published

2010
2010
2019
2019

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 20 publications
1
4
0
3
Order By: Relevance
“…Menard et al evaluated patients with PAD after exercise rehabilitative therapy using SF-36 and the WIQ, thus indicating that the WIQ showed an apparent improvement in walking distance, walking speed, and stair climbing 5 . WIQ is the most specific questionnaire for documenting the qualitative deficits of the patient with IC [6][7][8] . However, the current situation is that, even though it has been translated into various languages, such as French and German, the Japanese edition of the WIQ has not yet been widely used 9 .…”
Section: Discussionmentioning
confidence: 99%
“…Menard et al evaluated patients with PAD after exercise rehabilitative therapy using SF-36 and the WIQ, thus indicating that the WIQ showed an apparent improvement in walking distance, walking speed, and stair climbing 5 . WIQ is the most specific questionnaire for documenting the qualitative deficits of the patient with IC [6][7][8] . However, the current situation is that, even though it has been translated into various languages, such as French and German, the Japanese edition of the WIQ has not yet been widely used 9 .…”
Section: Discussionmentioning
confidence: 99%
“…The Incremental Shuttle Walking Test (ISWT) is a walking test which has previously been tested for validity and reliability and is safe for use in functional assessments of patients with vascular disease. [22][23][24] The ISWT is used to assess the distance that a patient walks at a controlled rhythm, which is set by audible signals recorded on a CD-ROM. 25 Walking speed is increased every minute, with increments indicated by three consecutive beeps.…”
Section: Methodsmentioning
confidence: 99%
“…Selecionou-se o TDBP, ou Shuttle Walk Test, com o intuito de mensurar a capacidade funcional 18 . Nesse teste, realiza-se um percurso com distância de 9 m, demarcado por dois cones, perfazendo uma distância total de 10 m. O teste é composto por 12 estágios e cada um tem a duração de 1 minuto.…”
Section: Medidasunclassified