2008
DOI: 10.1590/s1516-18462008000100011
|View full text |Cite
|
Sign up to set email alerts
|

Avaliação acústica e perceptivo-auditiva da voz nos momentos pré e pós-operatório da cirurgia de implante de pré-fáscia do músculo temporal

Abstract: (4) RESUMO Objetivo: analisar os parâmetros vocais acústicos e perceptivo-auditivos que se alteram com a cirurgia de implante de pré-fáscia do músculo temporal para sulco vocal estria maior. Métodos: registraramse as emissões vocais de 9 pacientes, 6 do sexo feminino e 3 do masculino, nas condições pré e pós-tratamento cirúrgico. As amostras vocais foram submetidas à avaliação perceptivo-auditiva por três fonoaudiólogas com experiência na área de voz, por meio de consenso utilizando a escala GRBAS e a análise … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
10
0
3

Year Published

2010
2010
2014
2014

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(15 citation statements)
references
References 18 publications
2
10
0
3
Order By: Relevance
“…it was considered consensus of the three examiners after reevaluation 24,25 . It is part of the research project approved by the Ethics Committee of the Federal University of Santa Maria, under number 0220.0.243.000-08.…”
Section: Resultsmentioning
confidence: 99%
“…it was considered consensus of the three examiners after reevaluation 24,25 . It is part of the research project approved by the Ethics Committee of the Federal University of Santa Maria, under number 0220.0.243.000-08.…”
Section: Resultsmentioning
confidence: 99%
“…For the study, it was established, as a criterion for normal voice, the average degree of 0.9 maximum on the aspects evaluated by the scale 12 . It was used Zoom H4n professional digital recorder with stereo unidirectional microphone (96KHz, 16bit), placed four centimeters from mouth at 90°1 2,20,24 . The recordings were performed at a room where the ambient noise was below 50dB NPS, measured using digital level sound pressure measurer Instrutherm Dec-480 2,24,25 .…”
Section: Fluxo Aéreo Adaptado E Coeficientes Fônicos De Futuros Profimentioning
confidence: 99%
“…It was used Zoom H4n professional digital recorder with stereo unidirectional microphone (96KHz, 16bit), placed four centimeters from mouth at 90°1 2,20,24 . The recordings were performed at a room where the ambient noise was below 50dB NPS, measured using digital level sound pressure measurer Instrutherm Dec-480 2,24,25 . Three judges underwent voice analysis independently, by the maximum phonation time (MPT) of the vowel /a/ of each subject of the target population.…”
Section: Fluxo Aéreo Adaptado E Coeficientes Fônicos De Futuros Profimentioning
confidence: 99%