2004
DOI: 10.1590/s0100-40422004000500013
|View full text |Cite
|
Sign up to set email alerts
|

A simplified procedure for determination of clofentezine residues in fruits by liquid chromatography with UV detection

Abstract: Recebido em 7/10/03; aceito em 23/1/04; publicado na web em 17/6/04 A rapid and sensitive method is described for the determination of clofentezine residues in apple, papaya, mango and orange. The procedure is based on the extraction of the sample with a hexane:ethyl acetate mixture (1:1, v/v) and liquid chromatographic analysis using UV detection. Mean recoveries from 4 replicates of fortified fruit samples ranged from 81% to 96%, with coefficients of variation from 8.9% to 12.5%. The detection and quantifica… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2006
2006
2016
2016

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(7 citation statements)
references
References 8 publications
0
7
0
Order By: Relevance
“…Since the compounds have amide bonds, the diode array detector was preferentially used at wavelengths around 225 nm instead of refraction index detector. 17,18 Owing to the fact that some compounds analysed have the same refraction index of the mobile phase, this detector was regarded as a second choice.…”
Section: Resultsmentioning
confidence: 99%
“…Since the compounds have amide bonds, the diode array detector was preferentially used at wavelengths around 225 nm instead of refraction index detector. 17,18 Owing to the fact that some compounds analysed have the same refraction index of the mobile phase, this detector was regarded as a second choice.…”
Section: Resultsmentioning
confidence: 99%
“…HPLC analysis (Navickiene & Ribeiro, 2004) was performed using a Shimadzu LC-20AD Prominence Liquid Chromatograph (Shimadzu, Tokyo, Japan) with a diode array detector (SPD-M20A). Separation was performed on a prepacked Nucleosil 100-5 C18, analytical column (250 mm  4.6 mm, 5 mm, MachereyeNagel, Duren, Germany) and the mobile phase consisted of methanolewater (70:30, v/v).…”
Section: Apparatusmentioning
confidence: 99%
“…The accuracy of the proposed method was determined by recovery assays and by comparing the results with those obtained from a previously published HPLC method (Navickiene & Ribeiro, 2004).…”
Section: Calibrationmentioning
confidence: 99%
See 2 more Smart Citations