1997
DOI: 10.1590/s0100-40421997000200004
|View full text |Cite
|
Sign up to set email alerts
|

Um fotômetro de fluxo para análises clínicas a base de um diodo emissor de luz bicolor

Abstract: Recebido em 21/3/96; aceito em 13/11/96 AN INEXPENSIVE FLOW PHOTOMETER FOR CLINICAL ANALYSIS BASED ON A BICOLOUR LIGHT EMITTING DIODE. The construction and evaluation of an inexpensive flowphotometer for clinical analysis, using a bicolour LED and a phototransistor adapted for tubular flow cell, are described. The instrument presents some new features such as: automatic zero, electronic calibration and peak-hold signal. When compared with a classical photometer, it is simpler and has the advantages of a flow a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0
2

Year Published

1999
1999
2012
2012

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 5 publications
0
3
0
2
Order By: Relevance
“…De fato, fotômetros simples, portáteis e de baixo custo, que empregam LED como fonte de radiação, têm sido desenvolvidos e usados em diversas aplicações analíticas [1][2][3][4][5][6][7] . Entre os fotômetros descritos na literatura, existem alguns que usam dois ou mais LEDs com máximos de emissão em diferentes comprimentos de onda, o que os tornam potencialmente aplicáveis a análises multicomponentes 2,8 .…”
Section: Diodos Emissores De Luz (Leds)unclassified
“…De fato, fotômetros simples, portáteis e de baixo custo, que empregam LED como fonte de radiação, têm sido desenvolvidos e usados em diversas aplicações analíticas [1][2][3][4][5][6][7] . Entre os fotômetros descritos na literatura, existem alguns que usam dois ou mais LEDs com máximos de emissão em diferentes comprimentos de onda, o que os tornam potencialmente aplicáveis a análises multicomponentes 2,8 .…”
Section: Diodos Emissores De Luz (Leds)unclassified
“…The system comprised a model IPC-8 Ismatec peristaltic pump provided with Tygon pumping tubes, a manifold build up with 0.8 i.d. Te¯on tubing, a home-made photometer similar to that described elsewhere [18], but operating with modulated frequency, a step-motor driven injector-commutator [19] including the BLED/ phototransistor set (® gure 1) , Perspex connectors and accessories. The light source was a BLED, with maximum wavelength and spectral bandwidth of 560 § 15 nm and 660 § 10 nm for green and red emission, respectively.…”
Section: T He Ow-injection Systemmentioning
confidence: 99%
“…5 Por outro lado, a complexidade de interpretação qualitativa dos espectros na região UV-Vis conduz à necessidade de utilização de ferramentas quimiométricas para reconhecimento de padrões. Diversos trabalhos foram publicados utilizando técnicas de reconhecimento de padrões, dentre os quais para amostras de vinhos, 6,7 carne de porco 8 e óleo de oliva, 9 apesar da perspectiva conceitual de que os espectros na região do visível serem pouco discriminativos.…”
Section: Introductionunclassified