2000
DOI: 10.1155/s1463924600000092
|View full text |Cite
|
Sign up to set email alerts
|

An improved leaping detector for flow analysis applied to iron speciation in drugs

Abstract: A low inner volume (ca. 64 ml) probe was built up in an injector-commutator in order to behave as a photometric leaping detector in flow analysis. It comprises a bicolour light-emitting diode (BLED), as a source of pulsed radiation in the red and green visible region, and two phototransistors as transducers. Sample injection, detector relocation, analytical signal recording, data treatment and definition of the spectral working range were computer-controlled. The feasibility of the system was initially demonst… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2003
2003
2018
2018

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(2 citation statements)
references
References 7 publications
0
2
0
Order By: Relevance
“…A solenoid mini-pump was used for fluid propelling [ 34 , 35 , 36 , 37 , 38 ]. In this work, the effect of residual measurement was considered to extend the linear response range, which is superior to other methods in phosphorus detection [ 39 , 40 , 41 , 42 ]. The effect of interferences is determined in order to demonstrate the selectivity of our device.…”
Section: Introductionmentioning
confidence: 99%
“…A solenoid mini-pump was used for fluid propelling [ 34 , 35 , 36 , 37 , 38 ]. In this work, the effect of residual measurement was considered to extend the linear response range, which is superior to other methods in phosphorus detection [ 39 , 40 , 41 , 42 ]. The effect of interferences is determined in order to demonstrate the selectivity of our device.…”
Section: Introductionmentioning
confidence: 99%
“…a UV/ visible spectrophotometer, to remote sites for in-situ monitoring. In flow spectrophotometry, multiple measurements on a processed sample are accomplished efficiently in order to permit implementation of simultaneous determinations, differential kinetic analysis, speciation, standard addition and blank compensation [5][6][7][8]. The present paper describes a brief performance evaluation of the photometric system that can be used for the continuous flow analysis of the determination of various parameters in clinical, environmental and food chemistry.…”
Section: Introductionmentioning
confidence: 99%