2003
DOI: 10.1590/s0034-70942003000600015
|View full text |Cite
|
Sign up to set email alerts
|

Marcapasso cardíaco artificial: considerações pré e per-operatórias

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0
4

Year Published

2009
2009
2019
2019

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(11 citation statements)
references
References 1 publication
(2 reference statements)
0
7
0
4
Order By: Relevance
“…Whenever possible, biphasic electrocautery (bipolar) should be used, since the electric current remains confined between the region of the surgery and the electrocautery, reducing the risk of leakage and interference with the device (244) (267) . In any case, the use of electrocautery should be minimized.…”
Section: Surgical Risk In Patients With Chronic Chagas Diseasementioning
confidence: 99%
See 2 more Smart Citations
“…Whenever possible, biphasic electrocautery (bipolar) should be used, since the electric current remains confined between the region of the surgery and the electrocautery, reducing the risk of leakage and interference with the device (244) (267) . In any case, the use of electrocautery should be minimized.…”
Section: Surgical Risk In Patients With Chronic Chagas Diseasementioning
confidence: 99%
“…Attention should be paid to the fact that the placement of the magnet should be restricted to the short periods of electrocautery use. The patient should be advised postoperatively to return to the clinic for pacemaker follow-up for the assessment of its operation and eventual reprogramming of its generator (267) .…”
Section: Surgical Risk In Patients With Chronic Chagas Diseasementioning
confidence: 99%
See 1 more Smart Citation
“…Artificial cardiac pacemakers are electronic devices of multiprogrammable stimulation that can replace electrical impulses and/or ectopic rhythms, to obtain the cardiac electrical activity as physiological as possible [52]. Since patients with pacemakers may have their heart rate modulated by such equipments, the analysis of HRV will not also reflect the autonomic modulation of the heart, limiting its use under this condition.…”
Section: Limitations On Usementioning
confidence: 99%
“…When this type of abnormality is detected, it can indicate pacemakers implantation, which consists of mechanisms of cardiac pacing, in order to correct or lessen the changes [2]. These electrical devices are responsible for providing cardiac electrical activity as physiological as possible, contributing primarily to correct heart rate and resynchronization of cardiac chambers [1,3].…”
Section: Introductionmentioning
confidence: 99%