2020
DOI: 10.1590/1980-5373-mr-2020-0162
|View full text |Cite
|
Sign up to set email alerts
|

A Comparative Study of Abbreviated Heat Treatments for SAE 4130 Steel After Laser Welding

Abstract: It was verified that SAE 4130 steel plates crack when laser beam welded at room temperature (RT). To overcome this problem, this work proposes a high temperature (HT) laser welding in order to reduce the residual stresses and create a bainitic structure instead of a martensitic one. A conventional post-welding heat treatment (PWHT) had been used as a comparison for HT. The centerline crack disappeared after a heat treatment of both in-situ (HT) or after inserting in a furnace (PWHT) at 500 °C for 10 minutes. T… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 13 publications
0
2
0
Order By: Relevance
“…Considering an isotherm at 1000 °C, the cooling rates at 40 and 100 μm were 32'280 and 21'434 °C/s, respectively. These rates are high enough to inhibit any long-range diffusional phase transformation, which promotes martensite formation [18]. However, as seen before, there was a small fraction of allotriomorphic ferrite in the FZ, both in condition B and in C. This ferrite must be a residue of the original BM that did not have time to dissolve in the austenitic matrix.…”
Section: Resultsmentioning
confidence: 74%
“…Considering an isotherm at 1000 °C, the cooling rates at 40 and 100 μm were 32'280 and 21'434 °C/s, respectively. These rates are high enough to inhibit any long-range diffusional phase transformation, which promotes martensite formation [18]. However, as seen before, there was a small fraction of allotriomorphic ferrite in the FZ, both in condition B and in C. This ferrite must be a residue of the original BM that did not have time to dissolve in the austenitic matrix.…”
Section: Resultsmentioning
confidence: 74%
“…Finite element analysis revealed a significant reduction in residual stress from 163.70 MPa to 3.72 MPa in the fusion zone (FZ) of the welds when transitioning from RT to HT. The study concludes that the hardness in the FZ is influenced by the microstructure resulting from the thermal cycle, with values of 400 HV for martensite (RT), 340 HV for tempered martensite (PWHT), and 250 HV for bainite (HT) [ 11 ].…”
Section: Introductionmentioning