The problem of complications arising after dental implantation is still relevant. The aim of the work was to investigate the effect of various types of removable appliances and dental implants on the oral microbiocenosis during orthopedic treatment of 64 people: 12 patients of the first index group, 40 patients of the second index group and 12 people of the control group. 6 months after the implants were installed, as a result of a microbiological study of the oral cavity, the differences were found in the qualitative composition of the microflora of the mucous membrane around the neck of the dental implant. In the first index group representatives of normal microflora prevailed. In 100% of cases Streptococcus vestibularis was isolated, from more than half patients S. oralis, S. mitis, Rothia mucilaginosa were isolated, S. gordonii was isolated from one patient. In the second index group, a significant diversity of microbial species was observed, including enterobacteria, which were isolated from 22.5% of the examined patients. In the control group, in addition to representatives of the normal microflora of the oral mucosa S. vestibularis (75.5%), S. oralis (50.0%), Neisseria subflava (66.7%) and Haemophylus parainfluenzae (50.0%) were found. From all patients of the control groups S. gordonii was isolated, as well as the other potentially pathogenic streptococci species, S. anginosus and S. constellatus by 66.7%. The type of removable appliances and dental implants used affects the microflora composition of the oral cavity, and, consequently, the further prognosis and the risk of complications. Collapsible dental implant supported removable prosthetic appliances with a metal frame and fixing elements, telescopic crowns and clasps less than other types of prosthetic appliances change the qualitative composition of the microflora of the oral mucosa around the neck of the dental implant.
Проблема осложнений, возникающих после проведения дентальной имплантации, остается актуальной. Целью работы было исследовать влияние различных видов съемных конструкций и дентальных имплантатов на микробиоценоз полости рта при ортопедическом лечении 64 человек: 12 пациентов 1-й основной группы, 40 пациентов 2-й основной группы и 12 человек группы контроля. Через 6 месяцев после установки имплантатов в результате микробиологического исследования полости рта были выявлены различия в качественном составе микрофлоры слизистой оболочки вокруг шейки дентального имплантата. В основной группе 1 преобладали представители нормальной микрофлоры. В 100% случаев выделен Streptococcus vestibularis, более чем у половины пациентов выделены S. oralis, S. mitis, Rothia mucilaginosa, S. gordonii выделен у одного пациента. В основной группе 2 отмечено значительное разнообразие видов микроорганизмов, включая энтеробактерии, которые были выделены у 22,5% обследованных. В контрольной группе помимо представителей нормальной микрофлоры слизистой оболочки полости рта обнаружены S. vestibularis (75,5%), S. oralis (50,0%), Neisseria subflava (66,7%) и Haemophylus parainfluenzae (50,0%). У всех пациентов контрольной группы были выделены S. gordonii, а также другие виды потенциально патогенных стрептококков — S. anginosus и S. constellatus по 66,7%. Вид используемых съемных конструкций и дентальных имплантатов влияет на состав микрофлоры полости рта, а, следовательно, на дальнейший прогноз и риск развития осложнений. Съемные ортопедические конструкции с металлическим каркасом и фиксирующими элементами, телескопическими коронками и замковыми креплениями с опорой на разборные дентальные имплантаты менее других видов конструкций изменяют качественный состав микрофлоры слизистой оболочки полости рта вокруг шейки дентального имплантата.
Ustanovka dental'nyh implantatov s primeneniem mekhanotronnyh ustrojstv poluchila shirokoe primenenie v nachale XXI v., naryadu s klassicheskim implantologicheskim protokolom. Oslozhneniya neredko obuslovleny nesoblyudeniem standarta hirurgicheskogo protokola provedeniya dental'noj implantacii i, kak sledstvie, povysheniem fokusa temperatury v meste sverleniya kostnoj tkani chelyustej. Cel'yu raboty bylo ocenit' fokus temperatury kostnoj tkani v oblasti ustanovki dental'nogo implantata, provodimoj po klassicheskoj metodike i s primeneniem mekhanotronnoj sistemy s razlichnoj stepen'yu ohlazhdeniya. V kachestve eksperimental'noj modeli ispol'zovali avital'nuyu skeletirovannuyu nizhnyuyu chelyust' porosenka v'etnamskoj vislobryuhoj porody. V sootvetstvii s klassicheskim hirurgicheskim protokolom bylo sformirovano vosprinimayushchee materinskoe lozhe. Issledovanie provodili v trekh rezhimah: pri otsutstvii podachi izotonicheskogo rastvora, pri neznachitel'nom ego ob"eme (25–30 ml/min) i pri oroshenii rastvorom v sootvetstvii s hirurgicheskim protokolom (75 ml/min). Temperatura podavaemogo izotonicheskogo rastvora sostavlyala 25 °S. Po rezul'tatam issledovaniya, i klassicheskaya metodika ustanovki cilindricheskih dental'nyh implantatov, i ih installyaciya s primeneniem mekhanotronnoj sistemy bezopasny pri uslovii soblyudeniya hirurgicheskogo protokola i s dostatochnym ob"emom podavaemogo izotonicheskogo rastvora.
Наиболее распространенной сложностью при постановке имплантатов является затрудненный выбор пространственного положения имплантатов. При интеграции имплантатов в полость рта две трети успеха операции зависят от того, насколько точно врач выберет позицию и угол наклона имплантата. Одной из важных проблем при установке имплантатов является их позиционирование в костном ложе. Целью работы было провести сравнительный анализ угловых отклонений дентальных имплантатов, установленных по классической методике, по «методу свободной руки» («free hand»). Использовали следующий алгоритм исследования. В декартовой системе координат на КТ-снимке в плоскости XОY (горизонтальная плоскость) определяли координаты шеек сравниваемых имплантатов у 34 исследуемых пациентов. Затем находили координаты апикальных частей всех исследуемых имплантатов. Полученные координаты помещали в разработанную нами программу ЭВМ № 2018661716 «Программа расчета угловых отклонений дентальных имплантатов», которая автоматически вычисляла угловое отклонение между осями установленных имплантатов. Расчет угловых отклонений между осями дентальных имплантатов у пациентов в послеоперационном периоде показал в 87% случаев значительное отклонение угла (до 27°) между осями имплантатов по сравнению с общепринятыми в дентальной имплантологии пределами (до 7°). В 100% изучаемых случаев не было отмечено параллельной установки дентальных имплантатов; анализ результатов дентальной имплантации в 1-м секторе выявил угловые отклонения в 27° 4`.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.