In order to explore effect of structure on the temperature sensitivity of partially carbonized carbon fibers, different heat treatment temperatures (700, 750 and 800 °C) and heat treatment times (3 and 9 min) were used to prepare fibers with different structures. The electrical resistivities were monitored whilst the room temperature was increased from 30 to 100 °C, which was used to characterize the temperature sensitivity. The fibers showed negative temperature coefficients in the temperature range. Infrared spectra, an element analysis, a scanning electron microscope (SEM), Raman spectroscopy and X-ray diffraction measurements were used to study the microstructure of the fibers. Through the analysis, the proportions of the graphite-like structure, graphitization degree and size of the graphite-like structure crystallite influenced the temperature sensitivity. The main electron transfer method used for the fibers was variable-range hopping. This indicated that the fibers had a potential application of preparing thermistors in polymer composites.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.