In this study, a novel non-invasive and contactless microwave sensor using a square substrate integrated waveguide (SIW) re-entrant cavity is proposed for complex permittivity measurement of chemical solutions. The working principle of this sensor is based on cavity perturbation technique, in which the resonant properties of cavity are utilized as signatures to extract the dielectric information of liquid under test (LUT). A winding microfluidic channel is designed and embedded in the gap region of the cavity to obtain a strong interaction between the induced electric field and LUT, thus achieving a high sensitivity. Also, a mathematical predictive model which quantitatively associates the resonant properties of the sensor with the dielectric constant of LUT is developed through numerical analysis. Using this predictive model, quick and accurate extraction of the complex permittivity of LUT can be easily realized. The performance of this sensor is then experimentally validated by four pure chemicals (hexane, ethyl acetate, DMSO and water) together with a set of acetone/water mixtures in various concentrations. Experimental results demonstrate that the designed sensor is capable of characterizing the complex permittivities of various liquids with an accuracy of higher than 96.76% (compared with the theoretical values obtained by Debye relaxation equations), and it is also available for quantifying the concentration ratio of a given binary mixture.
A compact dual-band bandpass filter implemented with an embedded coplanar waveguide (ECPW) resonator and a capacitively loaded resonator (CLR) in substrate integrated waveguide (SIW) cavity is presented and analyzed in this paper. Three transmission zeroes (TZs), of which two are located in the middle of the two passbands and one located in the upper stopband, are obtained to improve the inner-band isolation and the selectivity of the filter. The center frequencies and bandwidths of the two passbands can be easily tuned by changing the geometrical parameters of the two resonators. The proposed dual-band SIW filter is demonstrated with center frequencies located at 8.41/14.29 GHz. The measured insertion loss is −1.28/ − 1.91 dB with the corresponding fractional bandwidth (FBW) of 21.2%/7.3%. The measured results are in good agreement with the simulated ones.
High-voltage LiNi 0.8 Co 0.1 Mn 0.1 O 2 (NCM811)-based Li-ion batteries (LIBs) with enhanced performance can be achieved by properly tailoring the electrolyte systems. Benzoic anhydride (BA) was proposed here as a promising bifunctional electrolyte additive that can not only construct a robust cathode-electrolyte interface (CEI) film on the electrode surface but also capture HF/H 2 O in the electrolyte effectively. Compared to the cell without the BA additive, the capacity of Li/NCM811 half-cell with 1.0 wt % BA was increased from 128.5 to 149.6 mAh g À 1 after 200 cycles at 1 C between 3.0 and 4.3 V. Even at a higher cut-off voltage of 4.5 V, the BA-containing Li/NCM811 half-cell delivered a capacity retention of 69 % after 200 cycles, much higher than that of the half-cell without the additive (56 %). Both theoretical calculation and experimental results verified that the BA additive could be preferentially oxidized to form a stable interface film with high conductivity that protected the NCM811 cathode and suppressed the decomposition of the electrolyte.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.