In this work, a trivalent chromium conversion coating applied on AA2024-T351 alloy has been optimized for corrosion protection in sodium chloride solutions. Scanning electron microscopy, energy dispersive X-ray spectroscopy and electrochemical measurements were employed to characterize the coating. An immersion post-treatment of the coated alloy in 40 • C deionized water for 120 s considerably enhanced the corrosion protection properties, compared with a post treatment at 20 • C, or the absence of a post-treatment. Electrochemical noise measurements, combined with real time imaging, and potentiodynamic polarization experiments indicated a conversion treatment for 300 or 600 s provides optimal corrosion protection. Relatively long conversion treatments decreased the corrosion protection due to an increase in coating defects and cracks, especially around the second-phase particles.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.