• Modern CT provides excellent anatomical detail of congenital heart disease. • Dual source CT systems offer high-pitch spiral and sequential modes. • The high-pitch mode provides high accuracy for the assessment of CHD. • A few images using the high-pitch mode were occasionally slightly degraded. • But the high-pitch mode significantly lowers the radiation dose.
ObjectivesTo evaluate the feasibility of dose-modulated retrospective ECG-gated thoracoabdominal aorta CT angiography (CTA) assessing abdominal aortic intimal flap motion and investigate the motion characteristics of intimal flap in acute aortic dissection (AAD).Materials and Methods49 patients who had thoracoabdominal aorta retrospective ECG-gated CTA scan were enrolled. 20 datasets were reconstructed in 5% steps between 0 and 95% of the R-R interval in each case. The aortic intimal flap motion was assessed by measuring the short axis diameters of the true lumen and false lumen 2 cm above of celiac trunk ostium in different R-R intervals. Intimal flap motion and configuration was assessed by two independent observers.ResultsIn these 49 patients, 37 had AAD, 7 had intramural hematoma, and 5 had negative result for acute aortic disorder. 620 datasets of 31 patients who showed double lumens in abdominal aorta were enrolled in evaluating intimal flap motion. The maximum and minimum true lumen diameter were 12.2±4.1 mm (range 2.6∼17.4) and 6.7±4.1 mm (range 0∼15.3) respectively. The range of intimal flap motion in all patients was 5.5±2.6 mm (range 1.8∼10.2). The extent of maximum true lumen diameter decreased during a cardiac cycle was 49.5%±23.5% (range 12%∼100%). The maximum motion phase of true lumen diameter was in systolic phase (5%∼40% of R-R interval). Maximum and minimum intimal flap motion was at 15% and 75% of the R-R interval respectively. Intimal flap configuration had correlation with the phase of cardiac cycle.ConclusionsAbdominal intimal flap position and configuration varied greatly during a cardiac cycle. Retrospective ECG-gated thoracoabdominal aorta CTA can reflect the actual status of the true lumen and provide more information about true lumen collapse. This information may be helpful to diagnosis and differential diagnosis of dynamic abstraction.
CTA of peripheral arteries with a low tube voltage of 70 kV provides reliable information and serves as a rapidly performed and easily available "one-stop-shop" imaging modality in the diagnosis of peripheral arterial occlusion diseases.
PurposeTo compare the image quality and diagnostic accuracy between sinogram affirmed iterative reconstruction (SAFIRE) algorithm and filtered back projection (FBP) reconstruction algorithm at 70 kVp-tube-voltage DSCT angiography in children with congenital heart disease (CHD).Materials and MethodsTwenty-eight patients (mean age: 13 months; range: 2–48 months; male: 16; female: 12; mean weight: 8 kg) with CHD underwent 70 kVp DSCT angiography. Imaging data were reconstructed with both FBP and SAFIRE algorithms. Subjective image quality was evaluated on a five-point scale. The parameters of image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) on the objective image quality were compared for the two reconstruction algorithms. Surgery was performed in 20 patients, whereas conventional cardiac angiography (CCA) was performed in 8 patients. The diagnostic accuracy was evaluated on the surgical and/or CCA findings. The effective radiation doses were calculated.ResultsCompared to FBP algorithm, SAFIRE algorithm had significantly higher scores for subjective image quality (P<0.05), and lower image noise (P<0.05) as well as higher SNR &CNR values (P<0.05). There was no significant difference in the diagnostic accuracy between the FBP and SAFIRE algorithm (χ2 = 1.793, P>0.05). The mean effective dose for 70 kVp DSCT angiography was 0.30±0.13 mSv.ConclusionsThe SAFIRE algorithm can significantly reduce image noise and improve the image quality at 70 kVp DSCT angiography for the assessment of CHD in children.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.