A trace element copper (Cu2+) ion is the third most plentiful metal ion that necessary for all living organisms and playing a critical role in several processes. Nonetheless, according to cellular needs, deficient or excess Cu2+ ion cause various diseases. For all these reasons, optical sensors have been focused rapid Cu2+ ion detection in real-time with high selectivity and sensitivity. Optical sensors can measure fluorescence in the refractive index—adsorption from the relationships between light and matter. They have gained great attention in recent years due to the excellent advantages of simple and naked eye recognition, real-time detection, low cost, high specificity against analytes, a quick response, and the need for less complex equipment in analysis. This review aims to show the significance of Cu2+ ion detection and electively current trends in optical sensors. The integration of optical sensors with different systems, such as microfluidic systems, is mentioned, and their latest studies in medical and environmental applications also are depicted. Conclusions and future perspectives on these advances is added at the end of the review.
The accumulation of metal ions in the body is caused by human activities and industrial uses. Among these metal ions, copper is the third most abundant ion found in the human body and is indispensable for health because it works as a catalyst in the iron absorption processes. However, high doses of copper ions have been reported to generate various diseases. Different types of sensors are used to detect metal ions for several applications. To design selective and specific recognition sites on the sensor surfaces, molecular imprinting is one of the most used alteration methods to detect targets by mimicking natural recognition molecules. In this study, an ion-imprinted polymer-integrated plasmonic sensor was prepared to selectively detect copper (Cu(II)) ions in real-time. Following different characterization experiments, the Cu(II)-imprinted plasmonic sensor was employed for kinetic, selectivity, and reusability studies. According to the results, it was observed that this sensor can measure with 96% accuracy in the Cu(II) concentration range of 0.04–5 μM in buffer solution. The limit of detection and limit of quantification values were computed as 0.027 µM and 0.089 µM. The results also showed that this plasmonic sensor works successfully not only in a buffer solution but also in complex media such as plasma and urine.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.