Serum Lp-PLA(2) and hsCRP levels may play an important role in the association between periodontal disease and hyperlipidemia, and the control of these mediators may affect the inflammatory control of patients with hyperlipidemia and periodontal disease.
Abnormalities in the production and/or release of relaxing factors from the endothelium have been implicated in the development of hypertension in several animal models. Endothelium-dependent relaxation has been reported to be impaired in thoracic aorta in experimentally induced and genetically hypertensive rats. Present study has extented these observations to thoracic aorta of cadmium-hypertensive rats. The possible role of alterations in oxidant status was also studied. Hypertension was induced by the intraperitoneal administration of 1 mg/kg/day cadmium for 15 days. Mechanical responses produced by acetylcholine (ACh, 10(-9)-10(-4) M) and sodium nitroprusside (SNP, 10(-10)-10(-5) M) were studied on phenylephrine-precontracted thoracic aorta rings from control and cadmium-hypertensive rats. Serum nitric oxide (NO) and aortic malondialdehyde (MDA) levels were measured. ACh-induced relaxation was attenuated in aorta from cadmium-hypertensive rats, whereas relaxation responses to SNP did not differ significantly between the groups. Exposure of aortic rings to N(G)-nitro-L-arginine methyl ester (L-NAME, 10(-4) M) resulted in a significantly greater inhibition of relaxation response to ACh in aortic rings of cadmium-hypertensive rats as compared with control rats. Incubation with L-arginine (L-Arg, 10(-3) M) caused a similar reversal of the inhibition of ACh-induced relaxation by L-NAME in both groups. Serum NO levels were decreased and aortic MDA levels were increased in cadmium-treated rats as compared with control rats. However, the differences between the groups did not reach a statistical significance. These findings suggested that the reduction in endothelium-dependent relaxation may play a role in cadmium-induced hypertension as it was in many other hypertension models.
Background: This study was designed to use carnitine for preventing deposition of end products of lipid peroxidation in rat models in the prevention of ischemia-reperfusion (IR) damage frequently seen following operations of infrarenal abdominal aorta (AA). Methods: Forty male rats of Sprague-Dawley type were evenly (n = 8) randomized to five groups: sham laparotomy (SHAM), carnitine control (CC), aortic IR (AIR), AIR + low-dose carnitine (AIR+LDC), and AIR + high-dose carnitine (AIR+HDC). Results: Compared to other groups, serum creatinine levels of AIR group were significantly higher. Also tissue malondialdehyde (MDA) levels of AIR group were significantly higher compared to SHAM, CC, and AIR+HDC groups. In histopathological examination, although tubular necrosis atrophy and tubular degeneration observed in AIR group showed regression with low-dose carnitine, tubular necrosis atrophy, tubular degeneration, glomerular damage, and vascular congestion thrombosis decreased with high-dose carnitine. Total score of histological damage was significantly higher in AIR, AIR+LDC, and AIR+HDC groups compared to SHAM and CC groups. Moreover, total score of histological damage was significantly lower in AIR+HDC group than AIR+LDC group. Conclusions: In this study, we showed carnitine can partially prevent renal damage in infrarenal AIR models of rats. This result may open new prospects to us in the prevention of renal IR damage during surgery of aorta.
Despite the use of ionizing radiation and most of the harmful effects commonly known but not shown, insufficient attention has been observed for radiation protection. Radiation-exposed patients, physicians, health care team and staff should receive training in this field. The aim of this study is the doses of radiation in the operating room to identify and inform health personnel in radiation protection. Radiation exposure to operating room staff (doctor, nurse, medical staff, X-ray technician, anaesthesia technician, etc.) has been recognized as a necessary hazard in operating room. The purpose of our work is to determine operating room staff radiation doses for operating room to identify procedures associated with higher radiation doses, and to determine the effects of various parameters on staff doses. This study was performed at Suleyman Demirel University Medical Faculty Hospital. The procedure of study was performed in department of anaesthesia. We recorded that radiation doses data include all related imaging performed as part of department procedure. The distances were 100, 150, 250 cm from X-ray tube. It is important to understand that radiation affects medical staff in operating procedures. Use of low doses of ionizing radiation does not have knowledge of the long-term results but we need to be careful to conclude that use of radiological protection. During radiation protection, the maximum dose, even under the thick, the minimum degree of exposure to radiation is an important factor for our health. In addition, in the study, Philips BV-25 Gold is used as a brand fluoroscopic device. Device, 1.2-2 kV, 60-100 mA/s of doses between the values.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.