One gene can give rise to many functionally distinct proteoforms, each of which has a characteristic molecular mass. Top-down mass spectrometry enables the analysis of intact proteins and proteoforms. Here members of the Consortium for Top-Down Proteomics provide a decision tree that guides researchers to robust protocols for mass analysis of intact proteins (antibodies, membrane proteins and others) from mixtures of varying complexity. We also present cross-platform analytical benchmarks using a protein standard sample, to allow users to gauge their proficiency.
In recent years, there has been increasing interest in top-down mass spectrometry (TDMS) approaches for protein analysis, driven both by technological advancements and efforts such as those by the multinational Consortium for Top-Down Proteomics (CTDP). Today, diverse sample preparation and ionization methods are employed to facilitate TDMS analysis of denatured and native proteins and their complexes. The goals of these studies vary, ranging from protein and proteoform identification, to determination of the binding site of a (non)covalently-bound ligand, and in some cases even with the aim to study the higher order structure of proteins and complexes. Currently, however, no widely accepted terminology exists to precisely and unambiguously distinguish between the different types of TDMS experiments that can be performed. Instead, ad hoc developed terminology is often used, which potentially complicates communication of top-down and allied methods and their results. In this communication, we consider the different types of top-down (or top-down-related) MS experiments that have been performed and reported, and define distinct categories based on the protocol used and type(s) of information that can be obtained. We also consider the different possible conventions for distinguishing between middle- and top-down MS, based on both sample preparation and precursor ion mass. We believe that the proposed framework presented here will prove helpful for researchers to communicate about TDMS and will be an important step toward harmonizing and standardizing this growing field. Graphical Abstract
Pairing light and heavy chains in monoclonal antibodies (mAbs) using top-down (TD) or middle-down (MD) mass spectrometry (MS) may complement the sequence information on single chains provided by highthroughput genomic sequencing and bottom-up proteomics, favoring the rational selection of drug candidates. The 50 kDa F(ab) subunits of mAbs are the smallest structural units that contain the required information on chain pairing. These subunits can be enzymatically produced from whole mAbs and interrogated in their intact form by TD/MD MS approaches. However, the high structural complexity of F(ab) subunits requires increased sensitivity of the modern TD/MD MS for a comprehensive structural analysis. To address this and similar challenges, we developed and applied a multiplexed TD/MD MS workflow based on spectral averaging of tandem mass spectra (MS/MS) across multiple liquid chromatography (LC)−MS/MS runs acquired in reduced or full profile mode using an Orbitrap Fourier transform mass spectrometer (FTMS). We first benchmark the workflow using myoglobin as a reference protein, and then validate it for the analysis of the 50 kDa F(ab) subunit of a therapeutic mAb, trastuzumab. Obtained results confirm the envisioned benefits in terms of increased signal-to-noise ratio of product ions from utilizing multiple LC−MS/MS runs for TD/MD protein analysis using mass spectral averaging. The workflow performance is compared with the earlier introduced multiplexed TD/MD MS workflow based on transient averaging in Orbitrap FTMS. For the latter, we also report on enabling absorption mode FT processing and demonstrate its comparable performance to the enhanced FT (eFT) spectral representation.
The rules for product ion formation in electron capture dissociation (ECD) mass spectrometry of peptides and proteins remain unclear. Random backbone cleavage probability and the nonspecific nature of ECD toward amino acid sequence have been reported, contrary to preferential channels of fragmentation in slow heating-based tandem mass spectrometry. Here we demonstrate that for amphipathic peptides and proteins, modulation of ECD product ion abundance (PIA) along the sequence is pronounced. Moreover, because of the specific primary (and presumably secondary) structure of amphipathic peptides, PIA in ECD demonstrates a clear and reproducible periodic sequence distribution. On the one hand, the period of ECD PIA corresponds to periodic distribution of spatially separated hydrophobic and hydrophilic domains within the peptide primary sequence. On the other hand, the same period correlates with secondary structure units, such as ␣-helical turns, known for solution-phase structure. Based on a number of examples, we formulate a set of characteristic features for ECD of amphipathic peptides and proteins: (1) periodic distribution of PIA is observed and is reproducible in a wide range of ECD parameters and on different experimental platforms; (2) local maxima of PIA are not necessarily located near the charged site; (3) ion activation before ECD not only extends product ion sequence coverage but also preserves ion yield modulation; (4) the most efficient cleavage (e.g. global maximum of ECD PIA distribution) can be remote from the charged site; (5) the number and location of PIA maxima correlate with amino acid hydrophobicity maxima generally to within a single amino acid displacement; and (6) preferential cleavage sites follow a selected hydrogen spine in an ␣-helical peptide segment. Presently proposed novel insights into ECD behavior are important for advancing understanding of the ECD mechanism, particularly the role of peptide sequence on PIA. An improved ECD model could facilitate protein sequencing and improve identification of unknown proteins in proteomics technologies. In structural biology, the periodic/preferential product ion yield in ECD of ␣-helical structures potentially opens the way toward de novo site-specific secondary structure determination of peptides and proteins in the gas phase and its correlation with solution-phase structure. (J Am Soc Mass Spectrom 2009, 20, 1182-1192) © 2009 Published by Elsevier Inc. on behalf of American Society for Mass Spectrometry B iomolecular fragmentation in the gas phase by electron capture dissociation (ECD) [1-3] and electron-transfer dissociation (ETD) [4,5] is particularly attractive for mass spectrometry (MS)-based peptide and protein structural analysis. In ECD/ETD, interaction of a multiply charged peptide or protein ion with an electron/anion results in cleavage of NOC ␣ bonds along the peptide backbone, including chargesite-remote backbone cleavages [2]. ECD is useful for peptide sequence tag generation on a chromatographic timescale for protein identificat...
The Consortium for Top-Down Proteomics (CTDP) proposes a standardized notation, ProForma, for writing the sequence of fully characterized proteoforms. ProForma provides a means to communicate any proteoform by writing the amino acid sequence using standard one-letter notation and specifying modifications or unidentified mass shifts within brackets following certain amino acids. The notation is unambiguous, human-readable, and can easily be parsed and written by bioinformatic tools. This system uses seven rules and supports a wide range of possible use cases, ensuring compatibility and reproducibility of proteoform annotations. Standardizing proteoform sequences will simplify storage, comparison, and reanalysis of proteomic studies, and the Consortium welcomes input and contributions from the research community on the continued design and maintenance of this standard.
Successful electron capture dissociation (ECD) Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) applications to peptide and protein structural analysis have been enabled by constant progress in implementation of improved electron injection techniques. The rate of ECD product ion formation has been increased to match the liquid chromatography and capillary electrophoresis timescales, and ECD has been combined with infrared multiphoton dissociation in a single experimental configuration to provide simultaneous irradiation, fast switching between the two techniques, and good spatial overlap between ion, photon, and electron beams. Here we begin by describing advantages and disadvantages of the various existing electron injection techniques for ECD in FT-ICR MS. We next compare multiple-pass and single-pass ECD to provide better understanding of ECD efficiency at low and high negative cathode potentials. We introduce compressed hollow electron beam injection to optimize the overlap of ion, photon, and electron beams in the ICR ion trap. Finally, to overcome significant outgassing during operation of a powerful thermal cathode, we introduce nonthermal electron emitter-based electron injection. We describe the first results obtained with cold cathode ECD, and demonstrate a general way to obtain low-energy electrons in FT-ICR MS by use of multiple-pass ECD.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.