The microdosimetric spectra for high-energy beams of photons and proton, helium, carbon, neon, silicon and iron ions (LET = 0.5-880 keV/microm) were measured with a spherical-walled tissue-equivalent proportional counter at various depths in a plastic phantom. Survival curves for human tumor cells were also obtained under the same conditions. Then the survival curves were compared with those estimated by a microdosimetric model based on the spectra and the biological parameters for each cell line. The estimated alpha terms of the liner-quadratic model with a fixed beta value reproduced the experimental results for cell irradiation for ion beams with LETs of less than 450 keV/microm, except in the region near the distal peak.
We describe a method to calculate the relative biological effectiveness in mixed radiation fields of therapeutic ion beams based on the modified microdosimetric kinetic model (modified MKM). In addition, we show the procedure for integrating the modified MKM into a treatment planning system for a scanned carbon beam. With this procedure, the model is fully integrated into our research version of the treatment planning system. To account for the change in radiosensitivity of a cell line, we measured one of the three MKM parameters from a single survival curve of the current cells and used the parameter in biological optimization. Irradiation of human salivary gland tumor cells was performed with a scanned carbon beam in the Heavy Ion Medical Accelerator in Chiba (HIMAC), and we then compared the measured depth-survival curve with the modified MKM predicted survival curve. Good agreement between the two curves proves that the proposed method is a candidate for calculating the biological effects in treatment planning for ion irradiation.
Both the microdosimetric kinetic model (MKM) and the local effect model (LEM) can be used to calculate the surviving fraction of cells irradiated by high-energy ion beams. In this study, amorphous track structure models instead of the stochastic energy deposition are used for the MKM calculation, and it is found that the MKM calculation is useful for predicting the survival curves of the mammalian cells in vitro for (3)He-, (12)C- and (20)Ne-ion beams. The survival curves are also calculated by two different implementations of the LEM, which inherently used an amorphous track structure model. The results calculated in this manner show good agreement with the experimental results especially for the modified LEM. These results are compared to those calculated by the MKM. Comparison of the two models reveals that both models require three basic constituents: target geometry, photon survival curve and track structure, although the implementation of each model is significantly different. In the context of the amorphous track structure model, the difference between the MKM and LEM is primarily the result of different approaches calculating the biological effects of the extremely high local dose in the center of the ion track.
Purpose: Task Group (TG) 224 was established by the American Association of Physicists in Medicine's Science Council under the Radiation Therapy Committee and Work Group on Particle Beams. The group was charged with developing comprehensive quality assurance (QA) guidelines and recommendations for the three commonly employed proton therapy techniques for beam delivery: scattering, uniform scanning, and pencil beam scanning. This report supplements established QA guidelines for therapy machine performance for other widely used modalities, such as photons and electrons (TG 142, TG 40, TG 24, TG 22, TG 179, and Medical Physics Practice Guideline 2a) and shares their aims of ensuring the safe, accurate, and consistent delivery of radiation therapy dose distributions to patients. Methods: To provide a basis from which machine‐specific QA procedures can be developed, the report first describes the different delivery techniques and highlights the salient components of the related machine hardware. Depending on the particular machine hardware, certain procedures may be more or less important, and each institution should investigate its own situation. Results: In lieu of such investigations, this report identifies common beam parameters that are typically checked, along with the typical frequencies of those checks (daily, weekly, monthly, or annually). The rationale for choosing these checks and their frequencies is briefly described. Short descriptions of suggested tools and procedures for completing some of the periodic QA checks are also presented. Conclusion: Recommended tolerance limits for each of the recommended QA checks are tabulated, and are based on the literature and on consensus data from the clinical proton experience of the task group members. We hope that this and other reports will serve as a reference for clinical physicists wishing either to establish a proton therapy QA program or to evaluate an existing one.
The biological effects of radiation originate principally in damages to DNA. DNA damages by X rays as well as heavy ions are induced by a combination of direct and indirect actions. The contribution of indirect action in cell killing can be estimated from the maximum degree of protection by dimethylsulfoxide (DMSO), which suppresses indirect action without affecting direct action. Exponentially growing Chinese hamster V79 cells were exposed to high-LET radiations of 20 to 2106 keV/mum in the presence or absence of DMSO and their survival was determined using a colony formation assay. The contribution of indirect action to cell killing decreased with increasing LET. However, the contribution did not reach zero even at very high LETs and was estimated to be 32% at an LET of 2106 keV/mum. Therefore, even though the radiochemically estimated G value of OH radicals was nearly zero at an LET of 1000 keV/mum, indirect action by OH radicals contributed to a substantial fraction of the biological effects of high-LET radiations. The RBE determined at a survival level of 10% increased with LET, reaching a maximum value of 2.88 at 200 keV/mum, and decreased thereafter. When the RBE was estimated separately for direct action (RBE(D)) and indirect action (RBE(I)); both exhibited an LET dependence similar to that of the RBE, peaking at 200 keV/mum. However, the peak value was much higher for RBE(D) (5.99) than RBE(I) (1.89). Thus direct action contributes more to the high RBE of high-LET radiations than indirect action does.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.