Fixation superimposes a stiffer constraint on the mobility of the bridged segment than fusion. The current study suggested that the removal of spinal fixators after complete fusion could decrease the stress at adjacent segments. Through a minimally invasive procedure, we could reduce secondary damage to the paraspinal structures while removing the fixators, which is of utmost concern to surgeons.
Background: Lumbar spinal fusion with rigid spinal fixators as one of the high risk factors related to adjacentsegment failure. The purpose of this study is to investigate how the material properties of spinal fixation rods influence the biomechanical behavior at the instrumented and adjacent levels through the use of the finite element method. Methods: Five finite element models were constructed in our study to simulate the human spine pre-and postsurgery. For the four post-surgical models, the spines were implanted with rods made of three different materials: (i) titanium rod, (ii) PEEK rod with interbody PEEK cage, (iii) Biodegradable rod with interbody PEEK cage, and (iv) PEEK cage without pedicle screw fixation (no rods). Results: Fusion of the lumbar spine using PEEK or biodegradable rods allowed a similar ROM at both the fusion and adjacent levels under all conditions. The models with PEEK and biodegradable rods also showed a similar increase in contact forces at adjacent facet joints, but both were less than the model with a titanium rod. Conclusions: Flexible rods or cages with non-instrumented fusion can mitigate the increased contact forces on adjacent facet joints typically found following spinal fixation, and could also reduce the level of stress shielding at the bone graft.
Healing of an anterior cruciate ligament graft in bone tunnel yields weaker fibrous scar tissue, which may prolong an already prolonged healing process within the tendon–bone interface. In this study, gelatin molecules were added to thermosensitive chitosan/β-glycerol phosphate disodium salt hydrogels to form chitosan/gelatin/β-glycerol phosphate (C/G/GP) hydrogels, which were applied to 0.1 mg/mL collagenase carrier in the tendon–bone junction. New Zealand white rabbit’s long digital extensor tendon was detached and translated into a 2.5-mm diameter tibial plateau tunnel. Thirty-six rabbits underwent bilateral surgery and hydrogel injection treatment with and without collagenase. Histological analyses revealed early healing and more bone formation at the tendon–bone interface after collagenase partial digestion. The area of metachromasia significantly increased in both 4-week and 8-week groups after collagenase treatment (p < 0.01). Micro computed tomography showed a significant increase in total bone volume and bone volume/tissue volume in the 8 weeks after collagenase treatment, compared with the control group. Load-to-failure was significantly higher in the treated group at 8 weeks (23.8 ± 8.13 N vs 14.3 ± 3.9 N; p = 0.008). Treatment with collagenase digestion resulted in a 66% increase in pull-out strength. In conclusion, injection of C/G/GP hydrogel with collagenase improves tendon-to-bone healing in a rabbit model.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.