An on-line microdialysis/high-performance liquid chromatography method was developed for the simultaneous determination of melamine and cyanuric acid in non-dairy coffee creamer. To collect these analytes from aqueous samples, the microdialysis system featured a microdialysis probe incorporating a polyarylethersulfone membrane and employed 0.05 M HCl in 0.1% (v/v) MeOH as the perfusate, with optimal efficiency obtained at a flow rate of 1 μL min -1 . The chromatographic conditions were optimized when using a reverse-phase phenyl column and a mobile phase of phosphate buffer solution in 10% (v/v) MeOH, buffered at pH 3.0. Good linearity relationship (r 2 > 0.9987), intra-and inter-day precisions (RSDs < 6.6%), recoveries (96.9 -105.0%), and limits of detection (melamine, 3 ppb; cyanuric acid, 150 ppb) were observed for the two analytes. This method has been successfully applied to simultaneous determination of melamine and cyanuric acid in commercial creamers with the recoveries in the range of 97.5 to 102.6%.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.