PurposeTo evaluate the predictability of intraocular lens (IOL) power calculations using the IOLMaster and four different IOL power calculation formulas (Haigis, Hoffer Q, SRK II, and SRK/T) for cataract surgery in eyes with a short axial length (AL).MethodsThe present study was a retrospective comparative analysis which included 25 eyes with an AL shorter than 22.0 mm that underwent uneventful phacoemulsification with IOL implantation from July 2007 to December 2008 at Seoul National University Boramae Hospital. Preoperative AL and keratometric power were measured by the IOLMaster, and power of the implanted IOL was determined using Haigis, Hoffer Q, SRK II, and SRK/T formulas. Postoperative refractive errors two months after surgery were measured using automatic refracto-keratometry (Nidek) and were compared with the predicted postoperative power. The mean absolute error (MAE) was defined as the average of the absolute value of the difference between actual and predicted spherical equivalences of postoperative refractive error.ResultsThe MAE was smallest with the Haigis formula (0.37 ± 0.26 diopter [D]), followed by those of SRK/T (0.53 ± 0.25 D), SRK II (0.56 ± 0.20 D), and Hoffer Q (0.62 ± 0.16 D) in 25 eyes with an AL shorter than 22.0 mm. The proportion with an absolute error (AE) of less than 1 D was greatest in the Haigis formula (96%), followed by those in the SRK II (88%), SRK-T (84%), and Hoffer Q (80%).ConclusionsThe MAE was less than 0.7 D and the proportion of AE less than 1 D was more than 80% in all formulas. The IOL power calculation using the Haigis formula showed the best results for postoperative power prediction in short eyes.
Torsional phacoemulsification generated less heat than longitudinal phacoemulsification in all 3 comparison tests. Lower operating temperatures indicate lower heat generation within the same volume of fluid, and this may provide additional thermal protection during cataract surgery.
The phaco-chop technique requires lower ultrasound energy for nuclear management than the stop-and-chop technique in dense cataracts and the resulting endothelial loss was similar in both techniques.
PurposeTo describe etiologies and clinical characteristics of corneal opacities leading patients to seek cosmetic treatments.MethodsThe medical records of 401 patients who presented for cosmetic improvement in corneal opacities between May 2004 and July 2007 were retrospectively reviewed. The following parameters were analyzed: age, gender, cause of corneal opacity, time course of the corneal disease, associated diseases, prior and current cosmetic treatments, visual acuity, location and depth of the corneal opacity, and the presence of either corneal neovascularization or band keratopathy. A single practitioner examined all patients.ResultsThe most common causes of corneal opacity were ocular trauma (203 eyes, 50.6%), retinal disease (62 eyes, 15.5%), measles (38 eyes, 9.5%), and congenital etiologies (22 eyes, 5.5%). Prior treatments included iris colored contact lenses (125 eyes, 31.1%) and corneal tattooing (34 eyes, 8.46%). A total of 321 of 401 eyes underwent cosmetic treatment for corneal opacities. The most common treatment performed after the primary visit was corneal tattooing (261 eyes, 64.92%).ConclusionsThis is the first study to investigate the causes and clinical characteristics of patients presenting for cosmetic treatment of corneal opacities rather than for functional improvement. Various cosmetic interventions are available for patients with corneal opacities, and these should be individualized for the needs of each patient.
Purpose: To describe current cataract surgery practice patterns and trends among Korean ophthalmologists.Methods: A survey was conducted among members of the Korean Society of Cataract and Refractive Surgery (KSCRS) in October 2020. Of the 998 questionnaires, 262 (26.3%) were received for analysis. Data were analyzed using descriptive statistics and compared with those of previous surveys.
Results:The largest percentage of respondents (39%) had <5 years of practical experience, and 40% had >11 years of practical experience. The average, median, and mode monthly volumes of cataract surgeries performed by KSCRS members were 31, 20, and 10 cases, respectively. Topical anesthesia was administered by 85% of the respondents. For intraocular lens (IOL) calculations, 96% of the respondents used optical biometry. The proportion of surgeons providing femtosecond laserassisted cataract surgery (FLACS) increased significantly from 5% in 2018 to 29% in 2020. This increase was accompanied by an increase in the multifocal IOLs. Those who implant multifocal IOL for >10% of their cases increased from 16% (2018) to 29% (2020). Topical nonsteroidal antiinflammatory drugs were prescribed postoperatively by 76% of the respondents. Most respondents (70%) prescribed these anti-inflammatory drugs for 4 weeks.
Conclusions:This survey provided a comprehensive update on current cataract surgery practice in the Republic of Korea. The results highlighted the increasing use of premium IOLs, FLACS, optical biometry, and topical anesthesia to better meet the patients' needs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.