Even though the prognosis of LC from NSCLC is poor, small subsets of these patients survive longer. Our results suggest that more active treatment strategies including ITC, WBRT, and EGFR-TKI use might improve clinical outcomes in NSCLC patients with LC and good performance status, low initial CSF protein and WBC counts.
In LD-SCLC treatment, TRT starting in the third cycle of chemotherapy seemed to be noninferior to early TRT, and had a more favorable profile with regard to neutropenic fever.
This study aimed to evaluate the feasibility of combining helical tomotherapy (HT) and intensity‐modulated proton therapy (IMPT) in treating patients with nasopharynx cancer (NPC). From January 2016 to March 2018, 98 patients received definitive radiation therapy (RT) with concurrent chemotherapy (CCRT). Using simultaneous integrated boost and adaptive re‐plan, 3 different dose levels were prescribed: 68.4 Gy in 30 parts to gross tumor volume (GTV), 60 Gy in 30 parts to high‐risk clinical target volume (CTV), and 36 Gy in 18 parts to low‐risk CTV. In all patients, the initial 18 fractions were delivered by HT, and, after rival plan evaluation on the adaptive re‐plan, the later 12 fractions were delivered either by HT in 63 patients (64.3%, HT only) or IMPT in 35 patients (35.7%, HT/IMPT combination), respectively. Propensity‐score matching was conducted to control differences in patient characteristics. In all patients, grade ≥ 2 mucositis (69.8% vs 45.7%, P = .019) and grade ≥ 2 analgesic usage (54% vs 37.1%, P = .110) were found to be less frequent in HT/IMPT group. In matched patients, grade ≥ 2 mucositis were still less frequent numerically in HT/IMPT group (62.9% vs 45.7%, P = .150). In univariate analysis, stage IV disease and larger GTV volume were associated with increased grade ≥ 2 mucositis. There was no significant factor in multivariate analysis. With the median 14 month follow‐up, locoregional and distant failures occurred in 9 (9.2%) and 12 (12.2%) patients without difference by RT modality. In conclusion, comparable early oncologic outcomes with more favorable acute toxicity profiles were achievable by HT/IMPT combination in treating NPC patients.
PurposeIntensity modulated radiation therapy (IMRT) is a high precision therapy technique that can achieve a conformal dose distribution on a given target. However, organ motion induced by respiration can result in significant dosimetric error. Therefore, this study explores the dosimetric error that result from various patterns of respiration.Materials and MethodsExperiments were designed to deliver a treatment plan made for a real patient to an in-house developed motion phantom. The motion pattern; the amplitude and period as well as inhale-exhale period, could be controlled by in-house developed software. Dose distribution was measured using EDR2 film and analysis was performed by RIT113 software. Three respiratory patterns were generated for the purpose of this study; first the 'even inhale-exhale pattern', second the slightly long exhale pattern (0.35 seconds longer than inhale period) named 'general signal pattern', and third a 'long exhale pattern' (0.7 seconds longer than inhale period). One dimensional dose profile comparisons and gamma index analysis on 2 dimensions were performedResultsIn one-dimensional dose profile comparisons, 5% in the target and 30% dose difference at the boundary were observed in the long exhale pattern. The center of high dose region in the profile was shifted 1 mm to inhale (caudal) direction for the 'even inhale-exhale pattern', 2 mm and 5 mm shifts to exhale (cranial) direction were observed for 'slightly long exhale pattern' and 'long exhale pattern', respectively. The areas of gamma index >1 were 11.88%, 15.11%, and 24.33% for 'even inhale-exhale pattern', 'general pattern', and 'long exhale pattern', respectively. The long exhale pattern showed largest errors.ConclusionTo reduce the dosimetric error due to respiratory motions, controlling patient's breathing to be closer to even inhaleexhale period is helpful with minimizing the motion amplitude.
Purpose: To report the early clinical outcomes of combining intensity-modulated radiation therapy (IMRT) and intensity-modulated proton therapy (IMPT) in comparison with IMRT alone in treating oropharynx cancer (OPC) patients. Materials and Methods: The medical records of 148 OPC patients who underwent definitive radiotherapy (RT) with concurrent systemic therapy, from January 2016 till December 2019 at Samsung Medical Center, were retrospectively reviewed. During the 5.5 weeks’ RT course, the initial 16 (or 18) fractions were delivered by IMRT in all patients, and the subsequent 12 (or 10) fractions were either by IMRT in 81 patients (IMRT only) or by IMPT in 67 (IMRT/IMPT combination), respectively, based on comparison of adaptive re-plan profiles and availability of equipment. Propensity-score matching (PSM) was done on 76 patients (38 from each group) for comparative analyses. Results: With the median follow-up of 24.7 months, there was no significant difference in overall survival and progression free survival between groups, both before and after PSM. Before PSM, the IMRT/IMPT combination group experienced grade ≥ 3 acute toxicities less frequently: mucositis in 37.0% and 13.4% (p < 0.001); and analgesic quantification algorithm (AQA) in 37.0% and 19.4% (p = 0.019), respectively. The same trends were observed after PSM: mucositis in 39.5% and 15.8% (p = 0.021); and AQA in 47.4% and 21.1% (p = 0.016), respectively. In multivariate logistic regression, grade ≥ 3 mucositis was significantly less frequent in the IMRT/IMPT combination group, both before and after PSM (p = 0.027 and 0.024, respectively). AQA score ≥ 3 was also less frequent in the IMRT/IMPT combination group, both before and after PSM (p = 0.085 and 0.018, respectively). Conclusions: In treating the OPC patients, with comparable early oncologic outcomes, more favorable acute toxicity profiles were achieved following IMRT/IMPT combination than IMRT alone.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.