Robot-assisted endoscopic thyroidectomy by a gasless unilateral axillo-breast or axillary approach using a da Vinci S Surgical System robot is a safe, feasible, and cosmetically excellent procedure. It can be a promising alternative to endoscopic thyroidectomy or conventional open thyroidectomy.
To minimize surgical morbidity and neck scarring, minimally invasive thyroidectomy and robotic/endoscopic thyroidectomy via cervical, axillary, anterior chest, breast, postauricular or transoral approaches have been developed over the past 20 years. In this article, we review the evolution of robotic and endoscopic thyroid surgery and recent advances. Among remote access approaches, the gasless transaxillary approach, bilateral axillo-breast approach, postauricular facelift approach, and transoral vestibular approach are in common use today. Each procedure has its own advantages and disadvantages. Therefore, we need to understand these advantages and limitations, and to select the appropriate method for each patient. The most significant advantage of remote access thyroidectomy is its excellent cosmesis. The complication rate is similar in patients undergoing a remote access approach and those undergoing conventional surgery if the former is performed by experienced surgeons. Operative time is significantly longer in remote access thyroidectomy. In conclusion remote access thyroidectomy is feasible and its outcomes are comparable to those of conventional transcervical thyroidectomy in highly selected patients.
Postoperative voice function is better with robotic thyroidectomy using the GUAB approach than with conventional open thyroidectomy. This is an advantage of robotic thyroidectomy by the GUAB approach in addition to the excellent cosmesis.
Background: The aim of this study was to evaluate the safety and efficacy of transoral robotic and endoscopic thyroidectomy.
Methods:We analyzed and compared the first 100 cases of transoral robotic (71 cases) and endoscopic (29 cases) thyroidectomy with 207 cases of conventional transcervical thyroidectomy. Results: Transoral thyroidectomy was completed successfully in all patients, except for three who were converted to the robotic facelift or transcervical approach. The mean operative time of the transoral procedure was significantly longer than that of the conventional procedure. Perioperative complications such as hypoparathyroidism, vocal cord palsy, hematoma, and seroma did not differ between the two groups. However, there were some unusual complications such as CO 2 embolism, surgical site infection, skin trauma, burn, and ecchymosis in transoral thyroidectomy. Postoperative cosmesis was significantly better in the transoral group.Conclusion: Transoral robotic and endoscopic thyroidectomy is feasible and comparable to conventional transcervical thyroidectomy in highly selected patients.
K E Y W O R D Sendoscopic thyroidectomy, remote access thyroidectomy, robotic thyroidectomy, thyroid nodule, transoral thyroidectomy
A variety of electromyography (EMG) recording methods were reported during intraoperative neural monitoring (IONM) of recurrent laryngeal nerve (RLN) in thyroid surgery. This study compared two surface recording methods that were obtained by electrodes on endotracheal tube (ET) and thyroid cartilage (TC). This study analyzed 205 RLNs at risk in 110 patients undergoing monitored thyroidectomy. Each patient was intubated with an EMG ET during general anesthesia. A pair of single needle electrode was inserted obliquely into the TC lamina on each side. Standard IONM procedure was routinely followed, and EMG signals recorded by the ET and TC electrodes at each step were compared. In all nerves, evoked laryngeal EMG signals were reliably recorded by the ET and TC electrodes, and showed the same typical waveform and latency. The EMG signals recorded by the TC electrodes showed significantly higher amplitudes and stability compared to those by the ET electrodes. Both recording methods accurately detected 7 partial loss of signal (LOS) and 2 complete LOS events caused by traction stress, but only the ET electrodes falsely detected 3 LOS events caused by ET displacement during surgical manipulation. Two patients with true complete LOS experienced temporary RLN palsy postoperatively. Neither permanent RLN palsy, nor complications from ET or TC electrodes were encountered in this study. Both electrodes are effective and reliable for recording laryngeal EMG signals during monitored thyroidectomy. Compared to ET electrodes, TC electrodes obtain higher and more stable EMG signals as well as fewer false EMG results during IONM.
BackgroundThe relationship between the number of parathyroid glands preserved and hypoparathyroidism is not well understood. We sought to determine the number of parathyroid glands that need to be preserved to prevent hypoparathyroidism.MethodsWe analyzed 454 patients who underwent total thyroidectomy for papillary thyroid carcinoma. We analyzed the frequency of hypoparathyroidism according to the number of parathyroid glands preserved.ResultsIncidental parathyroidectomy occurred in 19.8% of the patients; one parathyroid gland in 17.6%, two in 1.5%, and three in 0.7%. Transient hypoparathyroidism was increased when incidental parathyroidectomy occurred (odds ratio 1.83, 95% confidence interval 1.04 to 3.23, P = 0.036) on multivariate regression analysis, but was not influenced by the actual number of parathyroid glands removed. There was no relationship between the number of parathyroid glands preserved and permanent hypoparathyroidism (P = 0.147).ConclusionsPreservation of all parathyroid glands decreases transient hypoparathyroidism compared with when three or fewer glands are preserved, but does not affect permanent hypoparathyroidism. During total thyroidectomy, preserving at least one parathyroid gland with an intact blood supply appears to be sufficient to prevent permanent hypoparathyroidism when autotransplantation is not performed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.