This study confirms the feasibility of transcutaneous recording of evoked laryngeal EMG during IONM. Although this study confirms the stability and accuracy of the transcutaneous approach, it also revealed the need for new electrode designs to improve EMG amplitudes before practical clinical application of this approach.
Background:Intraoperative neural monitoring (IONM) has gained widespread acceptance as an adjunct to the gold standard of visual identification of the recurrent laryngeal nerve (RLN) during thyroid surgery. Currently, laryngeal electromyography (EMG) recording during IONM is almost always performed using endotracheal tube (ETT) surface electrodes placed adjacent to vocal folds originating from the inner surface of the thyroid cartilage (TC). Therefore, we hypothesized that surface recording electrodes placed on the outer surface of the TC should enable access to the EMG response of the vocal folds during IONM. The aims of this Thyroid
Purpose: To examine the effect of hospital volume on positive surgical margin (PSM) and biochemical-failure-free survival (BFS) rates in patients with prostate cancer (PC) undergoing robotic-assisted or nonrobotic-assisted radical prostatectomy (RP). Patients and Methods: The patients were men collected in the National Taiwan Cancer Registry diagnosed as having PC without distant metastasis who received RP from 44 multi-institutes in Taiwan. The logistic regression method was used to analyze the risk from RP to PSM in included patients with hospital volume (i.e., number of patients with PC receiving robotic RP per year), and the Cox proportional hazards method was used to analyze the time from the index date to biochemical recurrence. Results: After propensity score adjustment, compared with hospitals with >100 patients/year, the adjusted odds ratios (aORs; 95% confidence intervals) of PSM in the robotic RP group in hospitals with 1–25, 26–50, and 51–100 patients/year were 2.25 (2.10–3.11), 1.42 (1.25–2.23), and 1.33 (1.13–2.04), respectively (type III p < 0.0001). Sensitivity analysis indicated that the aORs of PSM were 1.29 (1.07–1.81), 1.07 (0.70–1.19), and 0.61 (0.56–0.83), respectively, for patients receiving robotic RP compared with nonrobotic RP within hospitals with 1–25, 26–50, and 51–100 patients/year, respectively. Compared with hospitals with >100 patients/year, the adjusted hazard ratios (aHRs) of biochemical failure in the robotic RP group were 1.40 (1.04–1.67), 1.34 (1.06–1.96), and 1.31 (1.05–2.15) in hospitals with 1–25, 26–50, and 51–100 patients/year, respectively. Conclusions: Hospital volume significantly affected PSM and BFS in robotic RP, but not in nonrobotic RP. When patients with PC want to receive robotic RP, it should be performed in a relatively high-volume hospital (>100 patients/year).
Introduction: Titration of neuromuscular block (NMB) plays a key role in intraoperative recurrent laryngeal nerve monitoring during thyroid surgery. The combination of neuromuscular blocking agent and timely partial reversal of NMB was investigated in both animal experiments and clinical neuro-monitored thyroidectomy. Methods: In animal experiments, 8 piglets received sugammadex to assess the laryngeal EMG recovery after rocuronium-induced NMB. In clinical monitored thyroidectomy, 40 patients each were allocated to conventional group and sugammadex group. Conventional group received rocuronium 0.3 mg/kg at anesthesia induction, while sugammadex group received partial NMB recovery protocol-0.6 mg/kg of rocuronium at anesthesia induction and 0.5 mg/kg of sugammadex. Main outcome was assessed by first (V1) and final (V2) EMG signal induced by vagal stimulation.Results: In the porcine model, 50% recovery of laryngeal EMG amplitude was achieved at 16.8 ± 1.9 and 6 ± 2.7 minutes respectively after 0.5 and 1 mg/kg of sugammadex (p < 0.01). In monitored thyroidectomy, EMG amplitudes at V1 in group S and group C were 1214 ± 623 and 915 ± 476 lV, respectively (p ¼ 0.02). Positive and adequately high EMG amplitudes were observed at the early surgical stage for all patients. Sugammadex groups were superior to conventional group in EMG tube placement (p < 0.001). Conclusion: Both porcine model and clinical application showed that precise NMB management by low-dose sugammadex was effective for intraoperative neural monitoring (IONM). The regimen ensured optimal conditions for tracheal intubation and timely neuromuscular function restoration for high-quality EMG signal.
Over the past decade, the use of neuromonitoring in thyroid surgery has become well established and is increasing accepted across the world. In addition, new developments in energy devices have significantly improved efficacy in achieving hemostasis in thyroid surgery. Few studies focused on the complication rates in energy device-assisted sutureless neuro-monitored thyroidectomy. This study investigates a novel LigaSure Small Jaw (LSJ) technique for sutureless thyroidectomy and compares the surgical complication rates between LSJ and conventional clamp-and-tie technique in one thousand consecutive neuro-monitored thyroidectomy patients. Five hundred patients received sutureless thyroidectomy performed with LSJ (Group L), and 500 patients received surgery performed with conventional clamp-and-tie technique (Group C). Complication rates of postoperative hematoma, hypocalcemia and recurrent laryngeal nerve (RLN) palsy were compared between groups. The overall complication rates of hematoma, hypocalcemia (temporary/ permanent), and RLN (temporary/ permanent) palsy were 0.9%, 24.9% (24.6%/0.3%), and 1.7% (1.5%/0.2%), respectively. Group L and Group C significantly differed in postoperative hematoma rate (0.0% vs. 1.8%, respectively; p = 0.0026) and in postoperative hypocalcemia rate (20.1% vs. 30.0%, respectively; p = 0.0032). The incidence of RLN palsy did not significantly differ between Group L and Group C (1.38% vs. 2.08%; p = 0.2652). The overall surgical complication rates are low in neuro-monitored thyroidectomy. The LSJ is feasible for performing completely sutureless thyroidectomy and obtains superior outcomes of postoperative hematoma and hypocalcemia in comparison with clamp-and-tie hemostatic technique. The novel LSJ technique using double or overlapped sealing is useful for sutureless thyroidectomy. However, surgeons must carefully observe the tissue contraction that may reduce the LSJ-RLN distance and increase the risk of thermal injury during the LSJ activation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.