The paper presents a computational procedure developed for patient-specified blood flow simulation in the proximal anastomosis of femoral-popliteal bypass. The calculations are based on a three-dimensional geometric model constructed from a CT angiography scan of the vascular bed in the anastomotic region and boundary conditions obtained by ultrasound Doppler measurements of the velocity in control sections of the bed. A numerical analysis of 3D pulsating flow structure in a particular model of the proximal anastomosis has been carried out. The model includes sections of the common femoral artery (CFA), the graft, the deep femoral artery and the superficial femoral artery. The Reynolds number based on the CFA inner diameter and the inlet bulk velocity is 880. The sizes and location of stagnant zones, areas with low values of the time-averaged wall shear stress modulus and with high values of the oscillatory shear index are determined. It is shown that the results of the prediction of areas with low values of the time-averaged shear stress modulus are in qualitative agreement with the data of local measurements of neointima thickness formed along the graft wall one year after the operation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.