We reported recently that 1-bromopropane (1-BP; n-propylbromide, CAS Registry no. 106-94-5), an alternative to ozone-depleting solvents, is neurotoxic and exhibits reproductive toxicity in rats. The four most recent case reports suggested possible neurotoxicity of 1-BP in workers. The aim of the present study was to establish the neurologic effects of 1-BP in workers and examine the relationship with exposure levels. We surveyed 27 female workers in a 1-BP production factory and compared 23 of them with 23 age-matched workers in a beer factory as controls. The workers were interviewed and examined by neurologic, electrophysiologic, hematologic, biochemical, neurobehavioral, and postural sway tests. 1-BP exposure levels were estimated with passive samplers. Tests with a tuning fork showed diminished vibration sensation of the foot in 15 workers exposed to 1-BP but in none of the controls. 1-BP factory workers showed significantly longer distal latency in the tibial nerve than did the controls but no significant changes in motor nerve conduction velocity. Workers also displayed lower values in sensory nerve conduction velocity in the sural nerve, backward recalled digits, Benton visual memory test scores, pursuit aiming test scores, and five items of the Profile of Mood States (POMS) test (tension, depression, anxiety, fatigue, and confusion) compared with controls matched for age and education. Workers hired after May 1999, who were exposed to 1-BP only (workers hired before 1999 could have also been exposed to 2-BP), showed similar changes in vibration sense, distal latency, Benton test scores, and depression and fatigue in the POMS test. Time-weighted average exposure levels in the workers were 0.34–49.19 ppm. Exposure to 1-BP could adversely affect peripheral nerves or/and the central nervous system.
The purpose of this study was to evaluate the strategy of haploidentical (HID) stem cell combined with a small doses of umbilical cord blood (UCB) from a third-party donor transplantation (haplo-cord transplant) for treatment of myelodysplastic syndromes (MDS), by comparing with identical-sibling donor (ISD) transplantation. Eighty-five patients were included between January 2012 and December 2015, with a median 40 years old. Forty-eight patients received haplo-cord transplant and 37 patients received ISD transplant. Haplograft engraftment succeeded in all haplo-cord patients. For haplo-cord and ISD transplantation, adjusted cumulative incidences of grades 2-4 acute GvHD at 100 days were 27 and 11% (P=0.059); adjusted cumulative incidences of chronic GvHD at 2 years were 22 and 34% (P=0.215). The 2-year adjusted probabilities of overall survival were 64 and 70% (P=0.518), and of relapse-free survival were 56 and 66% (P=0.306). The 2-year adjusted cumulative incidences of relapse were 12 and 14% (P=0.743), and of non-relapse mortality were 33 and 23% (P=0.291). In conclusion, haplo-cord-HSCT achieves outcomes similar to those of ISD-HSCT for MDS and the haplo-cord-HSCT may potentially improve the outcome of HID- and UCB-HSCT alone. Thus, the haplo-cord transplantation may be a better valid alternative for MDS when an ISD is not available.
A species of bacterium with high chitosanase activity was isolated from soil samples in Haiyan City, China, and identified as an Acinetobacter species. This strain, named Acinetobacter sp. strain C-17, produced a chitosanase that was inducible and secreted into the medium. The optimal conditions for enzyme production were cells used to inoculate a medium containing 1% chitosan (pH 7.0) followed by culture at 30 degrees C. The chitosanase activity reached 1.7 U/ml when strain C-17 was incubated in a 250-ml flask under the optimal conditions for 24 h, and reached 2.8 U/ml when cells were incubated in a 3-l fermentor. The optimal pH and temperature for hydrolysis of chitosanase were 7.0 and 36 degrees C, respectively. The chitosanase activity was stable in the pH range of 5-8 and temperature range of 30-40 degrees C. The chitosanase of the strain was extracted by zinc acetate and ammonium sulfate precipitation. The molecular mass was estimated to be 35.4 kDa by SDS-PAGE.
Purpose: To retrospectively analyze the incidence and predictors of complications related to hookwire localization in patients with single and multiple nodules, and to evaluate the usefulness of a single-stage surgical method of single hookwire localization combined with video-assisted thoracoscopic surgery (VATS) in synchronous multiple pulmonary nodules (SMPNs). Methods: A total of 200 patients who underwent computed tomography (CT)-guided hookwire localization and subsequent VATS resection were enrolled in this study. For each patient, only 1 indeterminate nodule was implanted with a hookwire. There were 145 patients in the single-nodule group (Group S) and 55 in the multiple-nodule group (Group M). Univariate and binary logistic regression analyses were used to assess incidence and predictors of complications associated with hookwire localization. Results: The technical success rate of hookwire implantation was 97.5%. The incidence of pneumothorax and hookwire dislodgement was 17.0% and 2.5%, respectively. Binary logistic regression analysis showed that 1 transpleural puncture through the pleura (odds ratio [OR] = 0.433, P = .033) was the only independent protective factor for pneumothorax, and pneumothorax (OR = 26.114, P < .01) was the only independent risk factor for dislodgement. The volume of blood loss during VATS was significantly higher in group M than in group S, and the time of postoperative hospitalization was significantly longer in group M than in group S. About 44 patients in group M with additional 58 nodules without localization had undergone direct surgical resection simultaneously, and bilateral surgery was performed in 13 patients (29.5%). The intrathoracic recurrence rate was 4.8% during follow-up CT. Conclusion: Single-stage surgery via an approach of single hookwire localization combined with VATS is feasible and safe for SMPNs.
Background: Many studies have evaluated the association between matrix metalloproteinase 9 (MMP9) gene promoter polymorphism and diabetic microvascular complications. However, the results are conflicting and inconclusive. The aim of this meta-analysis was to evaluate the association more precisely. Materials and Methods: Studies were retrieved from the PubMed, Embase, Medline, China National Knowledge Infrastructure, Web of Science, and Cochrane databases. All statistical analyses were performed using Review Manager 5.2. Results: Data were abstracted from four case-control studies that included 446 patients with diabetic microvascular complications and 496 diabetic control subjects. The MMP9-1562 C/T genotype was significantly associated with the risk of diabetic nephropathy after stratification by specific type of microvascular complication (CT + TT vs. CC: OR = 0.42, 95% CI = 0.26–0.69, p = 0.0006; TT vs. CC + CT: OR = 0.37, 95% CI = 0.19–0.76, p = 0.006). Conclusions: This study adds to the evidence that MMP9-1562 T gene mutation might reduce the risk of diabetic nephropathy.
Aims/IntroductionChemokine ligand 5 (CCL5) is a member of the CC‐chemokine family expressed in various organs. It contributes to the migration of monocytes/macrophages into injured vascular walls by binding with its receptor chemokine receptor 5 (CCR5). Many studies have accessed the association between CCL5/CCR5 gene promoter polymorphisms and diabetic microvascular complications (DMI). However, the results are conflicting and inconclusive. The aim of the present study was to evaluate the association more precisely.Materials and MethodsTrials were retrieved through PubMed, Embase, Medline, China National Knowledge Infrastructure, Web of Science and Cochrane database without restrictions on language. The pooled odds ratio (OR) and 95% confidence interval (CI) were used to describe the strength of association with DMI.ResultsData were obtained from 11 case–control studies that included 2,737 DMI patients and 2,435 diabetic control subjects. In the overall analysis, the CCL5‐403 G/A and CCL5‐28 C/G gene polymorphisms were not significantly associated with the risk of DMI. However, CCR5‐59029 G/A was an independent risk factor of DMI in a dominant model (OR 1.77, 95% CI 1.06–2.97). Subgroup analysis showed that the risk of the CCR5 59029A‐positive genotype was significant in Asians (OR 2.08, 95% CI 1.68–2.57). In addition, the CCR5 59029A‐positive genotype was associated with increased risk of albuminuria.ConclusionsThere were no associations of CCL5 gene promoter polymorphism with the risk of DMI. However, the 59029A polymorphism in CCR5 might affect individual susceptibility for DMI.
This study investigated the efficacy and tolerability of pre-operative radiotherapy with concurrent capecitabine and oxaliplatin in patients with rectal cancer. Forty-seven patients with rectal adenocarcinoma (stages T3 - T4; node-positive) were enrolled and received radiotherapy (46 Gy in 23 fractions) in combination with capecitabine (1000 mg/m(2) twice daily on days 1 - 14 and 22 - 35) and oxaliplatin (130 mg/m(2) on days 1 and 22) (XELOX regimen). The main endpoints were safety and efficacy, as assessed by pathological complete response (pCR). All patients received pre-operative chemoradiotherapy (CRT) as planned. The most common severe toxicity was diarrhoea (12.8%); post-operative complications were rare (9.8%). The pCR rate was 20.9% in all patients and 34.8% in patients with normal pre-CRT serum carcinoembryonic antigen (CEA < or = 5 ng/ml) level, compared with 5.0% in the patients with elevated CEA (> 5 ng/ml). In conclusion, pre-operative radiotherapy with concurrent XELOX regimen in rectal cancer patients is feasible and effective. Serum CEA may be a suitable predictor of pCR.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.