Chest tomosynthesis is a low-dose, quasi-3D imaging modality that has been demonstrated to improve the detection sensitivity for small lung nodules, compared to 2D chest radiography. The purpose of this study is to investigate the feasibility and system requirements of stationary chest tomosynthesis (s-DCT) using a spatially distributed carbon nanotube (CNT) x-ray source array, where the projection images are collected by electronically activating individual x-ray focal spots in the source array without mechanical motion of the x-ray source, detector, or the patient. A bench-top system was constructed using an existing CNT field emission source array and a flat panel detector. The tube output, beam quality, focal spot size, system in-plane and in-depth resolution were characterized. Tomosynthesis slices of an anthropomorphic chest phantom were reconstructed for image quality assessment. All 75 CNT sources in the source array were shown to operate reliably at 80 kVp and 5 mA tube current. Source-to-source consistency in the tube current and focal spot size was observed. The incident air kerma reading per mAs was measured as 74.47 uGy mAs(-1) at 100 cm. The first half value layer of the beam was 3 mm aluminum. An average focal spot size of 2.5 × 0.5 mm was measured. The system MTF was measured to be 1.7 cycles mm(-1) along the scanning direction, and 3.4 cycles mm(-1) perpendicular to the scanning direction. As the angular coverage of 11.6°-34°, the full width at half maximum of the artifact spread function improved greatly from 9.5 to 5.2 mm. The reconstructed tomosynthesis slices clearly show airways and pulmonary vascular structures in the anthropomorphic lung phantom. The results show the CNT source array is capable of generating sufficient dose for chest tomosynthesis imaging. The results obtained so far suggest an s-DCT using a distributed CNT x-ray source array is feasible.
A prototype cone-beam CT (CBCT) head scanner featuring model-based iterative reconstruction (MBIR) has been recently developed and demonstrated the potential for reliable detection of acute intracranial hemorrhage (ICH), which is vital to diagnosis of traumatic brain injury and hemorrhagic stroke. However, data truncation (e.g., due to the head holder) can result in artifacts that reduce image uniformity and challenge ICH detection. We propose a multi-resolution MBIR method with an extended reconstruction field of view (RFOV) to mitigate truncation effects in CBCT of the head. The image volume includes a fine voxel size in the (inner) nontruncated region and a coarse voxel size in the (outer) truncated region. This multi-resolution scheme allows extension of the RFOV to mitigate truncation effects while introducing minimal increase in computational complexity. The multi-resolution method was incorporated in a penalized weighted least-squares (PWLS) reconstruction framework previously developed for CBCT of the head. Experiments involving an anthropomorphic head phantom with truncation due to a carbon-fiber holder were shown to result in severe artifacts in conventional single-resolution PWLS, whereas extending the RFOV within the multi-resolution framework strongly reduced truncation artifacts. For the same extended RFOV, the multi-resolution approach reduced computation time compared to the single-resolution approach (viz. time reduced by 40.7%, 83.0%, and over 95% for an image volume of 6003, 8003, 10003 voxels). Algorithm parameters (e.g., regularization strength, the ratio of the fine and coarse voxel size, and RFOV size) were investigated to guide reliable parameter selection. The findings provide a promising method for truncation artifact reduction in CBCT and may be useful for other MBIR methods and applications for which truncation is a challenge.
Technical assessment of the prototype demonstrates dose characteristics and imaging performance consistent with point-of-care detection and monitoring of head injury-most notably, conspicuous detection of ICH-and supports translation of the system to clinical studies.
Background. The predictive model of postsurgical recurrence for solitary early hepatocellular carcinoma (SE-HCC) is not well established. The aim of this study was to develop a novel model for prediction of postsurgical recurrence and survival for patients with hepatitis B virus (HBV)-related SE-HCC ≤10 cm. Patients and Methods. Data from 1,081 patients with HBVrelated SE-HCC ≤10 cm who underwent curative liver resection from 2003 to 2016 in our center were collected retrospectively and randomly divided into the derivation cohort (n = 811) and the internal validation cohort (n = 270). Eight hundred twenty-three patients selected from another four tertiary hospitals served as the external validation cohort. Postsurgical recurrence-free survival (RFS) and overall survival (OS) predictive nomograms were generated. The discriminatory accuracies of the nomograms were compared with six conventional hepatocellular carcinoma (HCC) staging systems. Results. Tumor size, differentiation, microscopic vascular invasion, preoperative α-fetoprotein, neutrophil-to-lymphocyte ratio, albumin-to-bilirubin ratio, and blood transfusion were identified as the risk factors associated with RFS and OS. RFS and OS predictive nomograms based on these seven variables were generated. The C-index was 0.83 (95% confidence interval [CI], 0.79-0.87) for the RFS-nomogram and 0.87 (95% CI, 0.83-0.91) for the OS-nomogram. Calibration curves showed good agreement between actual observation and nomogram prediction. Both C-indices of the two nomograms were substantially higher than those of the six conventional HCC staging systems (0.54-0.74 for RFS; 0.58-0.76 for OS) and those of HCC nomograms reported in literature. Conclusion. The novel nomograms were shown to be accurate at predicting postoperative recurrence and OS for patients with HBV-related SE-HCC ≤10 cm after curative liver resection. The Oncologist 2020;25:e1552-e1561 Implications for Practice: This multicenter study proposed recurrence or mortality predictive nomograms for patients with hepatitis B virus-related solitary early hepatocellular carcinoma ≤10 cm after curative liver resection. A close postsurgical surveillance protocol and adjuvant therapy should be considered for patients at high risk of recurrence.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.