Field measurements of spray drift are usually carried out by passive collectors and tracers. However, these methods are labour- and time-intensive and only provide point- and time-integrated measurements. Unlike these methods, the light detection and ranging (lidar) technique allows real-time measurements, obtaining information with temporal and spatial resolution. Recently, the authors have developed the first eye-safe lidar system specifically designed for spray drift monitoring. This prototype is based on a 1534 nm erbium-doped glass laser and an 80 mm diameter telescope, has scanning capability, and is easily transportable. This paper presents the results of the first experimental campaign carried out with this instrument. High coefficients of determination (R2 > 0.85) were observed by comparing lidar measurements of the spray drift with those obtained by horizontal collectors. Furthermore, the lidar system allowed an assessment of the drift reduction potential (DRP) when comparing low-drift nozzles with standard ones, resulting in a DRP of 57% (preliminary result) for the tested nozzles. The lidar system was also used for monitoring the evolution of the spray flux over the canopy and to generate 2-D images of these plumes. The developed instrument is an advantageous alternative to passive collectors and opens the possibility of new methods for field measurement of spray drift.
Pesticide spray drift poses health hazards to humans and causes a significant impact on the environment. In this work the capacity of an ad hoc light detection and ranging (LiDAR) system to differentiate spray nozzles according to their potential drift risk is evaluated for the first time.A total of 23 drift potential tests using 10 hollow-cone nozzles were carried out with the sprayer kept in a static position. Drift potential reduction (DPR) values of between 88.6% and 93.6% were obtained when comparing standard and drift reduction nozzle types. It was also possible to order different standard nozzle sizes according to their DPR. The LiDAR signal was correlated with several droplet size parameters measured by a phase Doppler particle analyzer (PDPA), being V 100 the best indicator. In the four field tests that were performed, the LiDAR system was also able to differentiate between standard and drift reduction nozzles under real application conditions, obtaining a DPR of 56.7%. The results of this work demonstrate that the developed LiDAR system is an advantageous alternative for the assessment of drift potential reduction.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.