Human bocavirus (HBoV) has been detected primarily in children with acute lower respiratory tract disease (LRTD), but its occurrence, clinical profile, and role as a causative agent of RTD are not clear. The aim of this study was to investigate the prevalence and the potential clinical relevance of HBoV. Using molecular tests, we tested 1352 nasopharyngeal samples obtained between October 1, 2017 and April 30, 2018 from children up to the age of 16 with RTD for the presence of HBoV DNA and 20 other respiratory pathogens at three different hospitals in Belgium. HBoV was detected in 77 children with a median age of 10.6 months. Consecutive samples were available for 15 HBoV-positive children and showed persistent HBoV positivity in four of them. Monoinfection was observed in six infants. Four of them were born prematurely and were infected during hospitalization at the neonatal intensive care unit (NICU). Only one of these six monoinfected children was diagnosed with recurrent wheezing due to HBoV. This child was carried to term and had a high viral load. Coinfections, most frequently with rhinovirus (52.1%) and adenovirus (49.3%), were observed in 72 patients. In seventeen of them in which HBoV was present at high viral load or higher viral load than its copathogens, bronchi(oli)tis (n = 8), recurrent wheezing (n = 8) or episodic wheezing (n = 1) were diagnosed. Our results suggest that HBoV infection at high viral load in infants is associated with wheezing (P = 0.013, Cramer's V = 0.613). Abbreviations BPDBronchopulmonary dysplasia CLD Chronic lung disease CPAP Continuous positive airway pressure Cq Quantitation cycle CRP C-reactive protein EV Enterovirus GI Gastrointestinal HAdV
Objective In this study, the performance of 2 commercially available SARS-CoV-2 antibody assays is evaluated. Methods The Siemens SARS-CoV-2 Total (COV2T) and IgG (COV2G) antibody tests were evaluated on a Siemens Atellica IM1300 analyzer. Imprecision was assessed with the CLSI EP15 protocol using positive controls. Ninety control group specimens were analyzed for specificity, and 175 specimens from 58 patients with polymerase chain reaction–confirmed SARS-CoV-2 were measured for the sensitivity and kinetics of the antibody response. Results Within-run and total imprecision were acceptable for both assays. Both tests showed a specificity of 100%. Sensitivity earlier in the disease state was greater for the COV2T assay than for the COV2G assay, but sensitivity >14 days after onset of symptoms approached 100% for both. For all patients, antibody titers remained above the seroconversion cutoff for all follow-up specimens. Conclusion This study shows acceptable performance for both the Siemens COV2T and COV2G test, although seroconversion occurs earlier with the COV2T test.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.