PurposeTo compare stereopsis and visual acuity (VA) between bilateral implantation of trifocal intraocular lenses (IOL) and blended implantation of an extended depth of focus (EDOF) IOL with a bifocal IOL.MethodsThis is a non-randomized, prospective comparative study included 74 eyes of 37 patients who underwent phacoemulsification and bilateral implantation of AT LISA tri 839MP IOL (bilateral group; 21 patients) or blended implantation of Tecnis Symfony ZXR00 and Tecnis ZLB00 IOL (blended group; 16 patients). The primary outcomes were stereoacuity and binocular VA. The secondary outcomes were visual defocus curve, quality of life, and patient satisfaction. Follow-up was performed 3 months after the surgery.ResultsThe mean near stereoacuity was 49.76 ± 22.67 and 120.63 ± 90.94 seconds of arc (arcsec) in the bilateral and blended groups, respectively (P < 0.001). Near stereoacuity was positively correlated with VA difference of two eyes (r = 0.896, P < 0.001). The mean binocular uncorrected visual acuity at 40 cm, 80 cm, 5 m, and corrected distance visual acuity at 5 m of the bilateral and blended groups was not statistically significant different. The bilateral group had better VA at a vergence from −2.5 to −4.0 D. Both groups obtained high quality of life and patient satisfaction scores.ConclusionThe bilateral and blended groups achieved good binocular VA, quality of life, and high patient satisfaction. However, the near stereoacuity of the blended group was worse.
To compare the visual outcomes and subjective experience of three intraocular lenses (IOL) implant strategies. Retrospective comparative study. This study comprised patients who underwent phacoemulsification and bilateral implantation of extended depth of focus (EDOF) IOL (ZXR00; EDOF group), blended implantation of EDOF and bifocal IOL (ZXR00/ZLB00; blended group), and bilateral implantation of trifocal IOL (AT LISA tri 839MP; trifocal group). The outcomes included visual acuity (VA), visual defocus curve, contrast sensitivity, visual quality, quality of life, spectacle independence, and patient satisfaction. Follow-up was performed 3 months after the surgery. This study included 114 eyes of 57 patients (20 in EDOF group; 16 in blended group; 21 in trifocal group). Patients in the three groups had high quality of life, patient satisfaction, and good contrast sensitivity. The EDOF group had the worst near VA, but the visual quality was the best. The blended group had good VA and slight photic disturbance. The trifocal group obtained the best whole range of VA, but the photic disturbance was significantly severe than the EDOF group. Both the blended and trifocal groups achieved high spectacle independence, but some patients in the EDOF group need spectacle when dealing with close-range tasks.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.