This 2020 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations (CoSTR) for neonatal life support includes evidence from 7 systematic reviews, 3 scoping reviews, and 12 evidence updates. The Neonatal Life Support Task Force generally determined by consensus the type of evidence evaluation to perform; the topics for the evidence updates followed consultation with International Liaison Committee on Resuscitation member resuscitation councils. The 2020 CoSTRs for neonatal life support are published either as new statements or, if appropriate, reiterations of existing statements when the task force found they remained valid. Evidence review topics of particular interest include the use of suction in the presence of both clear and meconium-stained amniotic fluid, sustained inflations for initiation of positive-pressure ventilation, initial oxygen concentrations for initiation of resuscitation in both preterm and term infants, use of epinephrine (adrenaline) when ventilation and compressions fail to stabilize the newborn infant, appropriate routes of drug delivery during resuscitation, and consideration of when it is appropriate to redirect resuscitation efforts after significant efforts have failed. All sections of the Neonatal Resuscitation Algorithm are addressed, from preparation through to postresuscitation care. This document now forms the basis for ongoing evidence evaluation and reevaluation, which will be triggered as further evidence is published. Over 140 million babies are born annually worldwide ( https://ourworldindata.org/grapher/births-and-deaths-projected-to-2100 ). If up to 5% receive positive-pressure ventilation, this evidence evaluation is relevant to more than 7 million newborn infants every year. However, in terms of early care of the newborn infant, some of the topics addressed are relevant to every single baby born.
Among preterm infants, delayed cord clamping did not result in a lower incidence of the combined outcome of death or major morbidity at 36 weeks of gestation than immediate cord clamping. (Funded by the Australian National Health and Medical Research Council [NHMRC] and the NHMRC Clinical Trials Centre; APTS Australian and New Zealand Clinical Trials Registry number, ACTRN12610000633088 .).
BACKGROUNDThe preferred timing of umbilical-cord clamping in preterm infants is unclear. METHODSWe randomly assigned fetuses from women who were expected to deliver before 30 weeks of gestation to either immediate clamping of the umbilical cord (≤10 seconds after delivery) or delayed clamping (≥60 seconds after delivery). The primary composite outcome was death or major morbidity (defined as severe brain injury on postnatal ultrasonography, severe retinopathy of prematurity, necrotizing enterocolitis, or late-onset sepsis) by 36 weeks of postmenstrual age. Analyses were performed on an intention-to-treat basis, accounting for multiple births. RESULTSOf 1634 fetuses that underwent randomization, 1566 were born alive before 30 weeks of gestation; of these, 782 were assigned to immediate cord clamping and 784 to delayed cord clamping. The median time between delivery and cord clamping was 5 seconds and 60 seconds in the respective groups. Complete data on the primary outcome were available for 1497 infants (95.6%). There was no significant difference in the incidence of the primary outcome between infants assigned to delayed clamping (37.0%) and those assigned to immediate clamping (37.2%) (relative risk, 1.00; 95% confidence interval, 0.88 to 1.13; P = 0.96). The mortality was 6.4% in the delayed-clamping group and 9.0% in the immediate-clamping group (P = 0.03 in unadjusted analyses; P = 0.39 after post hoc adjustment for multiple secondary outcomes). There were no significant differences between the two groups in the incidences of chronic lung disease or other major morbidities. CONCLUSIONSAmong preterm infants, delayed cord clamping did not result in a lower incidence of the combined outcome of death or major morbidity at 36 weeks of gestation than immediate cord clamping.
The International Liaison Committee on Resuscitation initiated a continuous review of new, peer-reviewed published cardiopulmonary resuscitation science. This is the fifth annual summary of the International Liaison Committee on Resuscitation International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations; a more comprehensive review was done in 2020. This latest summary addresses the most recently published resuscitation evidence reviewed by International Liaison Committee on Resuscitation task force science experts. Topics covered by systematic reviews in this summary include resuscitation topics of video-based dispatch systems; head-up cardiopulmonary resuscitation; early coronary angiography after return of spontaneous circulation; cardiopulmonary resuscitation in the prone patient; cord management at birth for preterm and term infants; devices for administering positive-pressure ventilation at birth; family presence during neonatal resuscitation; self-directed, digitally based basic life support education and training in adults and children; coronavirus disease 2019 infection risk to rescuers from patients in cardiac arrest; and first aid topics, including cooling with water for thermal burns, oral rehydration for exertional dehydration, pediatric tourniquet use, and methods of tick removal. Members from 6 International Liaison Committee on Resuscitation task forces have assessed, discussed, and debated the quality of the evidence, according to the Grading of Recommendations Assessment, Development, and Evaluation criteria, and their statements include consensus treatment recommendations or good practice statements. Insights into the deliberations of the task forces are provided in Justification and Evidence-to-Decision Framework Highlights sections. In addition, the task forces listed priority knowledge gaps for further research.
Automated FiO adjustment provides significant improvement of time in target saturations, reduces periods of hyperoxia, and severe hypoxia in preterm infants on positive pressure respiratory support.
CONTEXT: The International Liaison Committee on Resuscitation prioritized scientific review of umbilical cord management at term and late preterm birth. OBJECTIVE: To assess effects of umbilical cord management strategies (clamping timing and cord milking) in infants ≥34 weeks’ gestational age. DATA SOURCES: Cochrane Central Register of Controlled Trials, Medline, PubMed, Embase, Cumulative Index to Nursing and Allied Health Literature, and trial registries searched July 2019. STUDY SELECTION: Two authors independently assessed eligibility of randomized controlled trials. DATA EXTRACTION: Two authors independently extracted data and assessed evidence certainty (Grading of Recommendations Assessment, Development and Evaluations). RESULTS: We identified 46 studies (9159 women and their infants) investigating 7 comparisons. Compared with early cord clamping (ECC) <30 seconds, delayed cord clamping (DCC) ≥30 seconds (33 studies), intact-cord milking (1 study), and cut-cord milking (2 studies) probably improve hematologic measures but may not affect survival without neurodisability, anemia in early infancy, or maternal postpartum hemorrhage. No differences in major neonatal morbidities are seen in studies comparing methods of optimizing placental transfusion (DCC versus cut-cord milking [3 studies], longer delays in clamping [7 studies], or physiologic parameters [3 studies]). Strategies that promote increased placental transfusion may be associated with greater phototherapy use. Evidence for all outcomes was low or very low certainty. LIMITATIONS: Incompleteness and low certainty of findings limit applicability. CONCLUSIONS: Compared with ECC, DCC or cord milking increases hemoglobin and hematocrit immediately after birth in infants ≥34 weeks’ gestational age. The uncertain effects of DCC and cord milking compared with ECC on major morbidities limit usefulness of available evidence for policy and practice.
SPA was more painful than UC, as assessed by brow-bulging, and had a tendency to be associated with a higher rate of procedure failure. These findings should be taken into consideration when choosing between these 2 procedures for preterm infants who undergo urine sampling.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.