This work addresses a new mode of brittle failure that occurs in the bulk of tin-based lead-free solder joints, unlike the typical brittle failures that occur in the interfacial intermetallics. Brittle failures in the joint bulk result from the low-temperature ductile-to-brittle transition in the fracture behavior of b-tin. The bulk embrittlement of these joints is discussed by referring to the results of impact tests performed on both solder joints and bulk solder specimens. The mechanism of bulk embrittlement is largely explained based on the results of a fractography study performed on the bulk joint failures using scanning electron microscopy.
The low-temperature embrittlement of tin-based (Snbased) lead-free (Pb-free) solder alloys has been previously reported for bulk specimens tested in impact by means of a conventional Charpy V-notch test setup. [1][2] The brittle failure of Sn-based Pb-free solders at low temperatures (i.e. below -30ºC) is of great concern for electronic assemblies that operate at harsh conditions, because it can lead to occurrences of early failures. A miniaturized impact test setup has been devised to perform a scaled-down version of the conventional Charpy impact test on specimens, which lie in the size range of 300 µm to 3 mm. In this work, the impact tests have been carried out in the temperature range between 23°C and -110°C. The specimens consisted of SuperBGA ® (SBGA ® ) substrates bumped with 4 different solder alloys: Sn3%Ag0.5%Cu (SAC 305), Sn4%Ag0.5%Cu (SAC 405), Sn3.5%Ag, and Sn37%Pb. The energy absorbed during the fracture of the solder joints was seen to decrease as a function of temperature for the SAC 305 and SAC 405 alloys, while for the Sn37%Pb and Sn3.5%Ag this trend was less pronounced. The ductile-to-brittle transition in the fracture behavior of Snbased Pb-free solders was confirmed by scanning electron microscopy (SEM) investigations. These investigations showed the progressive bulk embrittlement of the Sn matrix of SAC 305 and SAC 405 solder alloys. The onset of the Sn embrittlement was observed between -40ºC and -50ºC leading to the complete brittle fracture of the solder joint at around -70ºC.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.