in coating cross sections. Transmission electron microspy (TEM) was carried out by using Tecnai F20 microscope equiped with Gatan UltraScan camera.Magnetization curves of the sprayed coatings were measured by a custombuilt vibrating sample magnetometer (VSM). Measurements were made both with the magnetic field in plane and perpendicularly to the plane. For calibration pure Ni sample was used.Wet corrosion tests were carried out in order to study the density of the coatings and location of the nickel particles in the alumina matrix. Anodic polarisation tests were performed for the coatings in an electrolyte of 3.0 wt.% NaCl in deionised water in two conditions pure 3.0 wt% NaCl (neutral) and with sulphur acid addition (pH 1).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.