In the Project TwinSkin at the IGS Institut für Gebäude-und Solartechnik (Institute for Building Services and Energy Design) Brunswick/Germany, nine office buildings with double skin glass faça-des (DSF) were i.a. acoustically evaluated. Double skin façades (DSF), in comparison with other kind of façades, are frequently promoted to provide higher sound insulation from external noise, especially road traffic noise. DSF offer the advantage of operable windows or doors to the cavity, which provide occupant comfort; however, than questions about the impairment of acoustic comfort arise. The objective was to thoroughly analyse the apparent sound insulation properties of DSF in the extended frequency range from 50 to 5000 Hz. Measurements were performed according to the standard EN ISO 140-5 for different operation conditions of the open ings and single number quantities were calculated. Additionally their respective spectrum adaptation terms (C and C tr ) were considered. A remarkable influence of DSF design on the sound in sulation properties was found. The results show high levels of weighted apparent sound reduction up to 60 dB, but also there were results from only 35 dB to 40 dB. Multi storey façades tend to better sound insulation performance in relation to the other types of DSF, an average of 13 dB higher values were found. Esthetical favourable arrangements of DSF can provide substantial negative influence on sound insulation. Akustischer Komfort in Bürogebäuden mit Doppelglasfassaden.In dem Projekt TwinSkin am IGS Institut für Gebäude-und Solartechnik Braunschweig wurden neun Bürogebäude mit Doppelglasfassaden (DGF) akustisch bewertet. Glasdoppelfassaden bieten gegenüber anderen Fassadenarten einen erhöhten Schutz der hinter der Fassade liegenden Räume vor von außen eindringendem Lärm, insbesondere Straßenverkehrslärm. Zudem kön-nen bei DSF Fenster oder Türen in den Fassadenzwischenraum geöffnet werden, was möglicherweise den Nutzerkomfort erhöht, aber Fragen über die Beeinträchtigung des akustischen Komforts entstehen lässt. Das Ziel der vorliegenden Arbeit war es, die vorhandene Schalldämmung von DSF im erweiterten Frequenzbereich von 50 bis 5000 Hz gründlich zu analysieren. Die Messungen wurden nach EN ISO 140-5 für die verschiedenen Betriebsbedingungen der Öffnungen durchgeführt und es wurden Einzahlangaben berechnet. Zusätzlich wurden die jeweiligen Spektrum-Anpassungswerte (C und C tr ) berücksichtigt. Es wurde ein bemerkenswerter Einfluss des DSF-Designs auf die Schalldämmungseigen-schaften gefunden. Die Ergebnisse zeigen ein hohes Schalldämm-Maß bis zu 60 dB, aber es wurden auch Ergebnisse von nur 35 dB und 40 dB gemessen. Mehrgeschossige Fassaden weisen im Vergleich zu den anderen Arten von DSF eine bessere Schalldäm-mung auf, wobei im Durchschnitt 13 dB höhere Werte gefunden wurden. Ästhetisch bevorzugte Gestaltungen der DSF können dagegen einen erheblichen negativen Einfluss auf die Schalldäm-mung haben.
The heat gains and daylight transmitted through windows directly influence the building's energy demand. High performance façades, when correctly specified, produce a great potential of energy savings by using daylight efficiently and controlling heat gains and/or losses. In Brazil, the lack of natural ventilation associated with large glass areas in office buildings exhibits substandard results concerning energy efficiency. This article demonstrates an approach to highly ventilated double skin façades in Brazil, investigating the potential of natural ventilation in accordance with the local climate. Applying the Light Design and Ideal Window Area methodologies, window areas as a function of different types of high performance glass are thermally simulated in the program EnergyPlus. The simulations are run for 10 cities in Brazil, in one of those cities, Curitiba (-25°25' 40''), the annual results of hourly simulations demonstrate the building energy demand as a function of window area, glass type, room ratio and size. The results concerning the energy efficiency perspective only illustrated that double skin façades could be applied for southern regions in Brazil and under certain criteria.Energieeffizienz von doppelschaligen Fassaden: eine Annähe-rung an brasilianische Klimabedingungen. Die ansteigende Temperatur und das Tageslicht, das ungehindert durch die Fenster tritt, beeinflussen den Energiehaushalt eines Gebäudes. Moderne Hochleistungsfassaden bieten bei korrekter Auslegung ein großes Potential zur Energieeinsparung, indem sie Tageslichtnutzung zulassen und solare Gewinne kontrollieren. Das Fehlen von natürli-chen Belüftungsmöglichkeiten und der hohe Anteil großflächiger Glasfassaden in Bürogebäuden führen in Brasilien zu unterdurchschnittlicher Energieeffizienz. Der Beitrag beschäftigt sich mit belüfteten doppelschaligen Fassaden in Brasilien, indem das Potential von natürlicher Belüftung unter den lokalen Klimabedingungen geprüft wird. In Anlehnung an Regeln der Kunstlichtplanung und zur Ermittlung der idealen Fensterfläche werden unterschiedliche Fensterflächenanteile unter Variation der Glasqualitäten in dem Programm EnergyPlus thermisch simuliert. Die Simulationen wurden für 10 brasilianische Städte durchgeführt. Die Jahresergebnisse der stündlichen Simulationen für Curitiba (-25°25' 40'') zeigen, dass der Energiebedarf des Gebäudes von der Größe der Fensterflächen, der Art der Glasscheiben sowie der Raumproportion und -größe abhängt. Die Ergebnisse bezüglich der Einschät-zung der Energieeffizienz weisen ferner darauf hin, dass doppelschalige Fassaden in südlichen Regionen von Brasilien und vergleichbaren Klimaten unter bestimmten Bedingungen angewendet werden können.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.