2010
DOI: 10.1016/j.buildenv.2009.10.006
|View full text |Cite
|
Sign up to set email alerts
|

Empirical thermal comfort evaluation of single and double skin façades

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 23 publications
(11 citation statements)
references
References 7 publications
0
11
0
Order By: Relevance
“…Such a phenomenon also highlights summer indoor comfort issues related to DSFs. Empirical field studies on a large number of real buildings seem to indicate that DSFs can be slightly better than single skins in terms of thermal comfort [86] but such an aspect falls outside the scope of this review. Figure 4 shows normalised data from the papers reviewed for this study in the form of cooling loads percentage reduction -findings are ranked from highest to lowest.…”
Section: Dsf Heating Loads Reduction Potentialmentioning
confidence: 95%
“…Such a phenomenon also highlights summer indoor comfort issues related to DSFs. Empirical field studies on a large number of real buildings seem to indicate that DSFs can be slightly better than single skins in terms of thermal comfort [86] but such an aspect falls outside the scope of this review. Figure 4 shows normalised data from the papers reviewed for this study in the form of cooling loads percentage reduction -findings are ranked from highest to lowest.…”
Section: Dsf Heating Loads Reduction Potentialmentioning
confidence: 95%
“…Also in the same year Kragh introduced the idea of mechanical ventilation of double skin facades and investigated their efficiency ( Kragh,2002). In the year 2010 Huckemann et al in an experimental research studied the effect of double skin facades on thermal comfort of the residents and the interior air quality and compared the results with one skin facades (Huckemann, 2010). In Iran Hashemi et al investigated the behavior of double skin ventilated facades for Tehran climate both experimentally and numerically (Hashemi, 2010).…”
Section: Double Skin Façadementioning
confidence: 99%
“…A double window system (DWS) is an energy-efficient envelope system in which a cavity is placed between the inner and outer layers to provide natural ventilation, solar radiation control, and enhanced insulation [1][2][3][4][5][6][7]. The DWS is a box-type double-skin facade that is also effective in reducing heating and cooling energy consumption [8][9][10][11]. In addition, buildings with double-skin facades offer better thermal comfort in the winter and lower thermal amplitude during the summer [10].…”
Section: Introductionmentioning
confidence: 99%
“…The DWS is a box-type double-skin facade that is also effective in reducing heating and cooling energy consumption [8][9][10][11]. In addition, buildings with double-skin facades offer better thermal comfort in the winter and lower thermal amplitude during the summer [10]. Compared to single-skin facades, the double-skin facades used in South Korea reduce energy consumption during the hot and temperate seasons without any additional energy input.…”
Section: Introductionmentioning
confidence: 99%