Abstract-Radio-frequency (RF) hepatic ablation, offers an alternative method for the treatment of hepatic malignancies. We employed finite-element method (FEM) analysis to determine tissue temperature distribution during RF hepatic ablation. We constructed three-dimensional (3-D) thermal-electrical FEM models consisting of a four-tine RF probe, hepatic tissue, and a large blood vessel (10-mm diameter) located at different locations. We simulated our FEM analyses under temperature-controlled (90 C) 8-min ablation. We also present a preliminary result from a simplified two-dimensional (2-D) FEM model that includes a bifurcated blood vessel. Lesion shapes created by the four-tine RF probe were mushroom-like, and were limited by the blood vessel. When the distance of the blood vessel was 5 mm from the nearest distal electrode 1) in the 3-D model, the maximum tissue temperature (hot spot) appeared next to electrods A. The location of the hot spot was adjacent to another electrode 2) on the opposite side when the blood vessel was 1 mm from electrode A. The temperature distribution in the 2-D model was highly nonuniform due to the presence of the bifurcated blood vessel. Underdosed areas might be present next to the blood vessel from which the tumor can regenerate.
Desmethylastemizole and astemizole cause equipotent block of HERG channels, and these are among the most potent HERG channel antagonists yet studied. Because desmethylastemizole becomes the dominant compound in serum, these findings support the postulate that it becomes the principal cause of long QT syndrome observed in patients following astemizole ingestion. Norastemizole block of HERG channels is weaker; thus, the risk of producing ventricular arrhythmias may be lower. These findings underscore the potential roles of some H1-receptor antagonist metabolites as K+ channel antagonists.
Finite element (FE) analysis has been utilised as a numerical tool to determine the temperature distribution in studies of radio frequency (RF) cardiac ablation. However, none of the previous FE analyses clarified such computational aspects as software requirements, computation time or convergence test. In addition, myocardial properties included in the previous models vary greatly. A process of FE modelling of a system that included blood, myocardium, and an ablation catheter with a thermistor embedded at the tip is described. The bio-heat equation is solved to determine the temperature distribution in myocardium using a commercial software application (ABAQUS). A Cauchy convergence test (epsilon = 0.1 degree C) was performed and it is concluded that the optimal number of elements for the proposed system is 24610. The effects of changes in myocardial properties (+/- 50% electric conductivity, +100%/-50% thermal conductivity, and +100%/-50% specific heat capacity) in both power-controlled (PCRFA) and temperature-controlled RF ablation (TCRFA) were studied. Changes in myocardial properties affect the results of the FE analyses of PCRFA more than those of TCRFA, and the maximum changes in lesion volumes were -58.6% (-50% electric conductivity), -60.7% (+100% thermal conductivity), and +43.2% (-50% specific heat).
We used the finite element method to study the effect of radio-frequency (RF) catheter ablation on tissue heating and lesion formation at different intracardiac sites exposed to different regional blood velocities. We examined the effect of application of RF current in temperature- and power-controlled mode above and beneath the mitral valve annulus where the regional blood velocities are high and low respectively. We found that for temperature-controlled ablation, more power was delivered to maintain the preset tip temperature at sites of high local blood velocity than at sites of low local blood velocity. This induced more tissue heating and larger lesion volumes than ablations at low velocity regions. In contrast, for power-controlled ablation, tissue heating was less at sites of high compared with low local blood velocity for the same RF power setting. This resulted in smaller lesion volumes at sites of low local velocity. Our numerical analyzes showed that during temperature-controlled ablation at 60 degrees C, the lesion volumes at sites above and underneath the mitral valve were comparable when the duration of RF current application was 10 s. When the duration of RF application was extended to 60 s and 120 s, lesion volumes were 33.3% and 49.4% larger above the mitral valve than underneath the mitral valve. Also, with temperature-controlled ablation, tip temperature settings of 70 degrees C or greater were associated with a risk of tissue overheating during long ablations at high local blood velocity sites. In power-controlled ablation (20 W), the lesion volume formed underneath the mitral valve was 165.7% larger than the lesion volume above the mitral valve after 10 s of ablation. We summarized the guidelines for energy application at low and high flow regions.
The anatomic and electrogram mapping approaches for ablation of the slow AV nodal pathway are comparable in efficacy and duration. If the anatomic approach is initially attempted and fails, the electrogram mapping approach may be successful at sites outside the areas targeted in the anatomic approach. With both the anatomic and electrogram mapping approaches, there are significant differences in the atrial electrogram configuration between successful and unsuccessful target sites.
The high current density at the edge of a metal electrode causes hot spots, which can lead to charring or blood coagulation formation during radio-frequency (RF) cardiac ablation. We used finite element analysis to predict the current density distribution created by several electrode designs for RF ablation. The numerical results demonstrated that there were hot spots at the edge of the conventional tip electrode and the insulating catheter. By modifying the shape of the edge of the 5-mm tip electrode, we could significantly reduce the high current density at the electrode-insulator interface. We also studied the current density distribution produced by a cylindrically shaped electrode. We modified the shape of a cylindrical electrode by recessing the edge and filled in a coating material so that the overall structure was still cylindrical. We analyzed the effects of depth of recess and the electrical conductivity of the added material. The results show that more uniform current density can be accomplished by recessing the electrode, adding a curvature to the electrode, and by coating the electrode with a resistive material.
Lesion size during radiofrequency catheter ablation in patients with paroxysmal supraventricular tachycardia (PSVT) is thought to be related to multiple factors, including contact pressure at the catheter-endocardial interface. Therefore a predictor of contact pressure at a potential target site for ablation might be useful. In this study 25 patients underwent duplicate 2 W applications of radiofrequency energy with the catheter in poor and firm contact with the right ventricular endocardium after successful ablation treatment for PSVT. The mean age of the patients was 44 +/- 15 years. Fifteen patients underwent slow pathway ablation for atrioventricular nodal reentrant tachycardia, and 10 patients underwent ablation for an accessory pathway. The mean impedance for low-energy applications in firm contact (139 +/- 24 ohms) was 22% +/- 13% greater (p 0.0001) than in poor contact with the right ventricle (113 +/- 16 ohms). The maximum impedance was 27% greater when the catheter was in firm (147 +/- 28 ohms) rather than poor contact (116 +/- 16 ohms), with the endocardium (p 0.0001). These results suggest that higher impedance measurements may be obtained with low-energy applications of 2 W when the ablation catheter is in firm contact with the endocardium.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.