Background: Venous thromboembolism (VTE), which includes deep vein thrombosis (DVT) and pulmonary embolism (PE), occurs in ∼1 to 2 individuals per 1000 each year, corresponding to ∼300 000 to 600 000 events in the United States annually. Objective: These evidence-based guidelines from the American Society of Hematology (ASH) intend to support patients, clinicians, and others in decisions about treatment of VTE. Methods: ASH formed a multidisciplinary guideline panel balanced to minimize potential bias from conflicts of interest. The McMaster University GRADE Centre supported the guideline development process, including updating or performing systematic evidence reviews. The panel prioritized clinical questions and outcomes according to their importance for clinicians and adult patients. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach was used to assess evidence and make recommendations, which were subject to public comment. Results: The panel agreed on 28 recommendations for the initial management of VTE, primary treatment, secondary prevention, and treatment of recurrent VTE events. Conclusions: Strong recommendations include the use of thrombolytic therapy for patients with PE and hemodynamic compromise, use of an international normalized ratio (INR) range of 2.0 to 3.0 over a lower INR range for patients with VTE who use a vitamin K antagonist (VKA) for secondary prevention, and use of indefinite anticoagulation for patients with recurrent unprovoked VTE. Conditional recommendations include the preference for home treatment over hospital-based treatment for uncomplicated DVT and PE at low risk for complications and a preference for direct oral anticoagulants over VKA for primary treatment of VTE.
The "GRADE-ADOLOPMENT" approach to guideline production combines adoption, adaptation, and, as needed, de novo development of recommendations. If developers of guidelines follow EtD criteria more widely and make their work publically available, this approach should prove even more useful.
IMPORTANCE The optimal oxygen saturation (SpO2) target for extremely preterm infants is unknown. OBJECTIVE To systematically review evidence evaluating the effect of restricted vs liberal oxygen exposure on morbidity and mortality in extremely preterm infants. DATA SOURCES MEDLINE, PubMed, CENTRAL, and CINAHL databases from their inception to March 31, 2014, and abstracts submitted to Pediatric Academic Societies from 2000 to 2014. STUDY SELECTION All published randomized trials evaluating the effect of restricted (SpO2, 85%–89%) vs liberal (SpO2, 91%–95%) oxygen exposure in preterm infants (<28 weeks’ gestation at birth). DATA EXTRACTION AND SYNTHESIS All meta-analyses were performed using Review Manager 5.2. The Cochrane risk-of-bias tool was used to assess study quality. The summary of the findings and the level of confidence in the estimate of effect were assessed using GRADEpro. Treatment effect was analyzed using a random-effects model. MAIN OUTCOMES AND MEASURES Death before hospital discharge, death or severe disability before 24 months, death before 24months, neurodevelopmental outcomes, hearing loss, bronchopulmonary dysplasia, necrotizing enterocolitis, and severe retinopathy of prematurity. RESULTS Five trials were included in the final synthesis. These studies had a similar design with a prespecified composite outcome of death/disability at 18 to 24 months corrected for prematurity; however, this outcome has not been reported for 2 of the 5 trials. There was no difference in the outcome of death/disability before 24 months (risk ratio [RR], 1.02 [95% CI, 0.92–1.14]). Mortality before 24 months was not different (RR, 1.13 [95% CI, 0.97–1.33]); however, a significant increase in mortality before hospital discharge was found in the restricted oxygen group (RR, 1.18 [95% CI, 1.03–1.36]). The rates of bronchopulmonary dysplasia, neurodevelopmental outcomes, hearing loss, and retinopathy of prematurity were similar between the 2 groups. Necrotizing enterocolitis occurred more frequently in infants on restricted oxygen (RR, 1.24 [95% CI, 1.05–1.47]). Using the Grades of Recommendation, Assessment, Development, and Evaluation (GRADE) criteria, we found that the quality of evidence for these outcomes was moderate to low. CONCLUSIONS AND RELEVANCE Although infants cared for with a liberal oxygen target had significantly lower mortality before hospital discharge than infants cared for with a restricted oxygen target, the quality of evidence for this estimate of effect is low. Necrotizing enterocolitis occurred less frequently in the liberal oxygen group. We found no significant differences in death or disability at 24 months, bronchopulmonary dysplasia, retinopathy of prematurity, neurodevelopmental outcomes, or hearing loss at 24 months.
BackgroundThere are diverse opinions and confusion about defining and including patient values and preferences (i.e. the importance people place on the health outcomes) in the guideline development processes. This article aims to provide an overview of a process for systematically incorporating values and preferences in guideline development.MethodsIn 2013 and 2014, we followed the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach to adopt, adapt and develop 226 recommendations in 22 guidelines for the Ministry of Health of the Kingdom of Saudi Arabia. To collect context-specific values and preferences for each recommendation, we performed systematic reviews, asked clinical experts to provide feedback according to their clinical experience, and consulted patient representatives.ResultsWe found several types of studies addressing the importance of outcomes, including those reporting utilities, non-utility measures of health states based on structured questionnaires or scales, and qualitative studies. Guideline panels used the relative importance of outcomes based on values and preferences to weigh the balance of desirable and undesirable consequences of alternative intervention options. However, we found few studies addressing local values and preferences.ConclusionsCurrently there are different but no firmly established processes for integrating patient values and preferences in healthcare decision-making of practice guideline development. With GRADE Evidence-to-Decision (EtD) frameworks, we provide an empirical strategy to find and incorporate values and preferences in guidelines by performing systematic reviews and eliciting information from guideline panel members and patient representatives. However, more research and practical guidance are needed on how to search for relevant studies and grey literature, assess the certainty of this evidence, and best summarize and present the findings.Electronic supplementary materialThe online version of this article (doi:10.1186/s12955-017-0621-0) contains supplementary material, which is available to authorized users.
Objective To examine the effect of transcatheter aortic valve implantation (TAVI) versus surgical replacement of an aortic valve (SAVR) in patients with severe aortic stenosis at low and intermediate risk of perioperative death.Design Systematic review and meta-analysisData sources Medline, Embase, and Cochrane CENTRAL.Study selection Randomized trials of TAVI compared with SAVR in patients with a mean perioperative risk of death <8%.Review methods Two reviewers independently extracted data and assessed risk of bias for outcomes important to patients that were selected a priori by a parallel guideline committee, including patient advisors. We used the GRADE system was used to quantify absolute effects and quality of evidence.Results 4 trials with 3179 patients and a median follow-up of two years were included. Compared with SAVR, transfemoral TAVI was associated with reduced mortality (risk difference per 1000 patients: −30, 95% confidence interval −49 to −8, moderate certainty), stroke (−20, −37 to 1, moderate certainty), life threatening bleeding (−252, −293 to −190, high certainty), atrial fibrillation (−178, −150 to −203, moderate certainty), and acute kidney injury (−53, −39 to −62, high certainty) but increased short term aortic valve reintervention (7, 1 to 21, moderate certainty), permanent pacemaker insertion (134, 16 to 382, moderate certainty), and moderate or severe symptoms of heart failure (18, 5 to 34, moderate certainty). Compared with SAVR, transapical TAVI was associated higher mortality (57, −16 to 153, moderate certainty, P=0.015 for interaction between transfemoral versus transapical TAVI) and stroke (45, −2 to 125, moderate certainty, interaction P=0.012). No study reported long term follow-up, which is particularly important for structural valve deterioration.Conclusions Many patients, particularly those who have a shorter life expectancy or place a lower value on the risk of long term valve degeneration, are likely to perceive net benefit with transfemoral TAVI versus SAVR. SAVR, however, performs better than transapical TAVI, which is of interest to patients who are not candidates for transfemoral TAVI.Systematic review registration PROSPERO CRD42016042879
Objective To determine the frequency of survival, stroke, atrial fibrillation, structural valve deterioration, and length of hospital stay after surgical replacement of an aortic valve (SAVR) with a bioprosthetic valve in patients with severe symptomatic aortic stenosis.Design Systematic review and meta-analysis of observational studies.Data sources Medline, Embase, PubMed (non-Medline records only), Cochrane Database of Systematic Reviews, and Cochrane CENTRAL from 2002 to June 2016.Study selection Eligible observational studies followed patients after SAVR with a bioprosthetic valve for at least two years.Methods Reviewers, independently and in duplicate, evaluated study eligibility, extracted data, and assessed risk of bias for patient important outcomes. We used the GRADE system to quantify absolute effects and quality of evidence. Published survival curves provided data for survival and freedom from structural valve deterioration, and random effect models provided the framework for estimates of pooled incidence rates of stroke, atrial fibrillation, and length of hospital stay.Results In patients undergoing SAVR with a bioprosthetic valve, median survival was 16 years in those aged 65 or less, 12 years in those aged 65 to 75, seven years in those aged 75 to 85, and six years in those aged more than 85. The incidence rate of stroke was 0.25 per 100 patient years (95% confidence interval 0.06 to 0.54) and atrial fibrillation 2.90 per 100 patient years (1.78 to 4.79). Post-SAVR, freedom from structural valve deterioration was 94.0% at 10 years, 81.7% at 15 years, and 52% at 20 years, and mean length of hospital stay was 12 days (95% confidence interval 9 to 15).Conclusion Patients with severe symptomatic aortic stenosis undergoing SAVR with a bioprosthetic valve can expect only slightly lower survival than those without aortic stenosis, and a low incidence of stroke and, up to 10 years, of structural valve deterioration. The rate of deterioration increases rapidly after 10 years, and particularly after 15 years.
The version presented here may differ from the published version or from the version of the record. Please see the repository URL above for details on accessing the published version and note that access may require a subscription.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.