2014
DOI: 10.1038/jp.2014.199
|View full text |Cite
|
Sign up to set email alerts
|

Oxygen targeting in preterm infants: a physiological interpretation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

2
65
0
1

Year Published

2015
2015
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 73 publications
(69 citation statements)
references
References 43 publications
2
65
0
1
Order By: Relevance
“…3,20 Pulse oximeters estimate arterial oxygen saturation within limits of accuracy, such that 1 standard deviation equals 3%. 10,16,21 Thus, an oxygensaturation value of 88% could reflect an arterial oxygen saturation between 85 and 91% in 68% of infants, but it may fall outside a range of 82 to 94% in up to 5% of infants. Variations in the location of the probe and the proportion of fetal hemoglobin may influence these limits 16 but should create no bias, because randomization tends to balance such factors evenly between groups.…”
mentioning
confidence: 99%
See 3 more Smart Citations
“…3,20 Pulse oximeters estimate arterial oxygen saturation within limits of accuracy, such that 1 standard deviation equals 3%. 10,16,21 Thus, an oxygensaturation value of 88% could reflect an arterial oxygen saturation between 85 and 91% in 68% of infants, but it may fall outside a range of 82 to 94% in up to 5% of infants. Variations in the location of the probe and the proportion of fetal hemoglobin may influence these limits 16 but should create no bias, because randomization tends to balance such factors evenly between groups.…”
mentioning
confidence: 99%
“…10,16,21 Thus, an oxygensaturation value of 88% could reflect an arterial oxygen saturation between 85 and 91% in 68% of infants, but it may fall outside a range of 82 to 94% in up to 5% of infants. Variations in the location of the probe and the proportion of fetal hemoglobin may influence these limits 16 but should create no bias, because randomization tends to balance such factors evenly between groups. However, because pulse oximeters underestimate hypoxemia with progressively wider limits of accuracy as true oxygen-saturation values decrease from 93% to 80%, 21 substantially more infants in the lower-target group than in the higher-target group may have been exposed to values of partial pressure of arterial oxygen below the previously recommended levels, 22 with associated adverse effects.…”
mentioning
confidence: 99%
See 2 more Smart Citations
“…The risk-of-bias category was graded as moderate due to a lack of separation in the target saturations. 31 A maximal separation of 6% was intended by using a masking algorithm that allowed gradual reduction to no separation outside of the target SpO 2 range. 31 -33 We acknowledge that quality of evidence is subjective and should not be penalized, if maintaining SpO 2 within a target range is exclusively due to clinical and practical factors.…”
Section: Discussionmentioning