A novel LC-MS/MS method was developed for the quantification of the new cyclin dependent kinase inhibitors (CDKIs) palbociclib and ribociclib and the aromatase inhibitor letrozole used in combinatory regimen. The proposed method is appropriate to be applied in clinical practice due to the simple and fast sample preparation based on protein precipitation, the low amount of patient sample necessary for the analysis (10 μL) and the total run time of 6.5 min. It was fully validated according to FDA and EMA guidelines on bioanalytical method validation. The linearity was assessed (R 2 within 0.9992-0.9983) over the concentration ranges of 0.3-250 ng/mL for palbociclib, 10-10000 ng/mL for ribociclib and 0.5-500 ng/mL for letrozole that properly cover the therapeutic plasma concentrations. A specific strategy was implemented to reduce the carryover phenomenon, formerly known for these CDKIs. This method was applied to quantify the C min of palbociclib, ribociclib and letrozole in plasma samples from patients enrolled in a clinical study. The same set of study samples was analysed twice in separate runs to assess the reproducibility of the method by means of the incurred samples reanalysis. The results corroborated the reliability of the analyte concentrations obtained with the bioanalytical method, already proved by the validation process. The percentage differences were always within ±10% for all the analytes and the R 2 of the correlation graph between the two quantifications was equal to 0.9994. OPEN ACCESS Citation: Posocco B, Buzzo M, Poetto AS, Orleni M, Gagno S, Zanchetta M, et al. (2020) Simultaneous quantification of palbociclib, ribociclib and letrozole in human plasma by a new LC-MS/MS method for clinical application. PLoS ONE 15(2): e0228822.
The introduction of imatinib, an oral tyrosine kinase inhibitor, as first-line standard therapy in patients with unresectable, metastatic, or recurrent gastro-intestinal stromal tumor (GIST), strongly improved their treatment outcomes. However, therapeutic drug monitoring (TDM) is recommended for this drug due to the large inter-individual variability in plasma concentration when standard dose is administered. A Cmin higher than 760 ng/mL was associated with a longer progression free survival. Thus, a LC-MS/MS method has been developed and fully validated to quantify imatinib and its active metabolite, norimatinib, in finger-prick dried blood spot (DBS). The influence of hematocrit, sample homogeneity, and spot size and the correlation between finger-prick and venous DBS measurements were also assessed. The method showed a good linearity (R2 > 0,996) between 50–7500 ng/mL for imatinib and 10–1500 ng/mL for norimatinib. Analytes were extracted from DBS samples by simply adding to 3 mm-discs 150 μL of acidified methanol containing IMA-D8. The collected extract was then injected on a LC Nexera system in-house configured for the on-line cleanup, coupled with an API-4000 QT. The chromatographic separation was conducted on a Synergi Fusion-RP column (4 μm, 2x50 mm) while the trapping column was a POROS R1/20 (20 μm, 2x30 mm). The total run time was 8.5 min. DBSs stored at room temperature in plastic envelopes containing a silica-gel drying bag were stable up to 16 months.The proposed method was applied to 67 clinical samples, showing a good correlation between patients’ finger-prick DBS and plasma concentrations, measured by the reference LC-MS/MS method, internally validated. Imatinib and norimatinib concentrations found in finger-prick DBS were adjusted by hematocrit or by an experimental correction factor to estimate the corresponding plasma measurements. At the best of our knowledge, the proposed LC-MS/MS method is the first analytical assay to measure imatinib and norimatinib in DBS samples.
Background Anticancer drugs are notoriously characterized by a low therapeutic index, the introduction of therapeutic drug monitoring (TDM) in oncologic clinical practice could therefore be fundamental to improve treatment efficacy. In this context, an attractive technique to overcome the conventional venous sampling limits and simplify TDM application is represented by dried blood spot (DBS). Despite the significant progress made in bioanalysis exploiting DBS, there is still the need to tackle some challenges that limit the application of this technology: one of the main issues is the comparison of drug concentrations obtained from DBS with those obtained from reference matrix (e.g., plasma). In fact, the use of DBS assays to estimate plasma concentrations is highly dependent on the chemical-physical characteristics of the measured analyte, in particular on how these properties determine the drug partition in whole blood. Methods In the present review, we introduce a critical investigation of the DBS-to-plasma concentration conversion methods proposed in the last ten years and applied to quantitative bioanalysis of anticancer drugs in DBS matrix. To prove the concordance between DBS and plasma concentration, the results of statistical tests applied and the presence or absence of trends or biases were also considered.
Gold nanoparticles (AuNPs) covered with mixtures of immiscible ligands present potentially anisotropic surfaces that can modulate their interactions at complex nano–bio interfaces. Mixed, self‐assembled, monolayer (SAM)‐protected AuNPs, prepared with incompatible hydrocarbon and fluorocarbon amphiphilic ligands, are used here to probe the molecular basis of surface phase separation and disclose the role of fluorinated ligands on the interaction with lipid model membranes and cells, by integrating in silico and experimental approaches. These results indicate that the presence of fluorinated amphiphilic ligands enhances the membrane binding ability and cellular uptake of gold nanoparticles with respect to those coated only with hydrogenated amphiphilic ligands. For mixed monolayers, computational results suggest that ligand phase separation occurs on the gold surface, and the resulting anisotropy affects the number of contacts and adhesion energies with a membrane bilayer. This reflects in a diverse membrane interaction for NPs with different surface morphologies, as determined by surface plasmon resonance, as well as differential effects on cells, as observed by flow cytometry and confocal microscopy. Overall, limited changes in monolayer features can significantly affect NP surface interfacial properties, which, in turn, affect the interaction of SAM‐AuNPs with cellular membranes and subsequent effects on cells.
Lenvatinib (LENVA) is an oral antineoplastic drug used for the treatment of hepatocellular carcinoma and thyroid carcinoma. LENVA therapeutic drug monitoring (TDM) should be mandatory for a precision medicine to optimize the drug dosage. To this end, the development of a sensitive and robust quantification method to be applied in the clinical setting is essential. The aim of this work was to develop and validate a sensitive, rapid, and cost-effective LC-MS/MS method for the quantification of LENVA in human plasma. On this premise, sample preparation was based on a protein precipitation and the chromatographic separation was achieved on a Synergi Fusion RP C18 column in 4 min. The method was completely and successfully validated according to European Medicines Agency (EMA) and Food and Drug Administration (FDA) guidelines, with good linearity in the range of 0.50–2000 ng/mL (R≥0.9968). Coefficient of variation (CV) for intra- and inter-day precision was ≤11.3% and accuracy ranged from 96.3 to 109.0%, internal standard normalized matrix effect CV% was ≤2.8% and recovery was ≥95.6%. Successful results were obtained for sensitivity (signal to noise (S/N) ratio >21) and selectivity, dilution integrity (CV% ≤ 4.0% and accuracy 99.9–102%), and analyte stability under various handling and storage conditions both in matrix and solvents. This method was applied to quantify LENVA in patient’s plasma samples and covered the concentration range achievable in patients. In conclusion, a sensitive and robust quantification method was developed and validated to be applied in the clinical setting.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.