Background: COVID-19 is a global pandemic. The virus spreads through respiratory droplets and close contact. Therefore, the availability of personal protective equipment (PPE) for healthcare professionals is essential. 3D printing technology could represent a valid option to ameliorate PPE shortages.
Methodology: Custom-made face mask were designed on the basis of facial scan and then 3D-printed. The whole protocol is executed with freeware software and only required a 3D printer. Six healthcare workers wore the device weekly thus expressing a judgment regarding quality of work, respiratory and skin comfort.
Results: The estimated total cost of a single mask is approximately 5 USD. The virtual design of a complete mask lasted 68 minutes on average. Most healthcare workers rated comfort as very good.
Conclusions: Based on the encouraging results obtained, we can confidently confirm that custom-made masks are novel and useful devices that may be used in the fight against COVID-19.
Background. Among patients with diagnosis of Laryngeal Squamous Cell Carcinoma (LSCC), up to 37.5% of cases may have occult metastasis (OM), and this feature is linked to poor prognosis and high rate of local recurrence. The role of elective neck dissection (END) in clinically negative neck (cN0) LSCC remains controversial. It is of great value to search for low-cost and easily detectable indicators to predict the risk of OM in laryngeal cancer. Recent reports have shown that high values of the neutrophil-to-lymphocyte ratio (NLR) and platelet-to-lymphocyte ratio (PLR) represent a negative prognostic factor in head and neck cancers. The aim of our study has been to investigate the value of pre-treatment NLR and PLR with regard to predicting occult cervical metastasis in cN0 supraglottic and glottic LSCC. Materials and methods. Data of patients affected by LSCC, who had been surgically treated by means of laryngectomy (total, horizontal partial and supracricoid) and END between January 2006 and January 2021, were retrospectively reviewed, using information retrieved from a database dedicated to such procedures in a single tertiary care referral institute. Results. A total of 387 patients were treated for LSCC at our Institute from 2006 to 2021, but only 108 of them met the inclusion criteria. The median age at the time of diagnosis was 64 years (range, 39–89 years). All the tumors were treated with a laryngectomy and an END. A total of 27.7% of patients were found positive for neck node metastasis (the pN+ group), while 78/108 (72.3%) patients were found to be negative for the presence of neck metastasis (the pN0 group). High values of NLR, but not PLR, significantly correlated with the probability of OM, and according to the iterative algorithm of Newton–Raphson, an NLR value of 2.26 corresponds to a probability of OM of 20%. Conclusion. Our analysis revealed a statistical correlation between high NLR pre-treatment values and positive neck OM in patients with LSCC.
Background: The first applications of computer-aided design/computer-aided manufacturing (CAD/CAM) in maxillofacial surgery date back to the 1980s. Since then, virtual surgical planning (VSP) has undergone significant development and is now routinely used in daily practice. Indeed, in an extraordinary period, such as that of the current COVID-19 pandemic, it offers a valuable tool in relation to the protection of healthcare workers. In this paper we provide a comprehensive summary of the clinical applications reported in the literature and review our experience using an in-house rapid prototyping technique in the field of maxillofacial surgery. methods: Our research was focused on reconstructive surgery, traumatology (especially in relation to orbital floor and zygomatic arch fractures), and COVID-19 masks. The first step was a radiographic study. Next, computed tomography (CT) scans were segmented in order to obtain a three-dimensional (3D) model. Finally, in the editing phase, through the use of specific software, a customized device for each patient was designed and printed. results: Four reconstructive procedures were performed with a perfect fitting of the surgical device produced by means of VSP. In nine orbital floor fracture cases a good overlapping of the mesh on the orbital floor was obtained. In sixteen zygomatic arch cases the post-operative CT scan showed an excellent fitting of the device and a correct fracture reduction. Regarding the COVID-19 period, six masks and shields produced proved to provide effective protection. conclusions: The timescale and costs required for the production of our “home-made” virtual design are low, which makes this method applicable to a large number of cases, for both ordinary and extraordinary activities.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.