Background Titanium is a commonly used inert bio-implant material within the medical and dental fields. Although the use of titanium is thought to be safe with a high success rate, in some cases, there are rare reports of problems caused by titanium. In most of these problematic reports, only individual reports are dominant and comprehensive reporting has not been performed. This comprehensive article has been prepared to review the toxicity of titanium materials within the medical and dental fields. Methods We used online searching tools including MEDLINE (PubMed), Embase, Cochrane Library, and Google Scholar by combining keywords such as “titanium implant toxicity,” “titanium implant corrosion,” “titanium implant allergy,” and “yellow nail syndrome.” Recently updated data has been collected and compiled into one of four categories: “the toxicity of titanium,” “the toxicity of titanium alloys,” “the toxicity of titanium implants,” and “diseases related to titanium.” Results Recent studies with regard to titanium toxicity have been increasing and have now expanded to the medical field in addition to the fields of environmental research and basic science. Problems that may arise in titanium-based dental implants include the generation of titanium and titanium alloy particles and ions deposited into surrounding tissues due to the corrosion and wear of implants, resulting in bone loss due to inflammatory reactions, which may lead to osseointegration failure of the dental implant. These titanium ions and particles are systemically deposited and can lead to toxic reactions in other tissues such as yellow nail syndrome. Additionally, implant failure and allergic reactions can occur due to hypersensitivity reactions. Zirconia implants can be considered as an alternative; however, limitations still exist due to a lack of long-term clinical data. Conclusions Clinicians should pay attention to the use of titanium dental implants and need to be aware of the problems that may arise from the use of titanium implants and should be able to diagnose them, in spite of very rare occurrence. Within the limitation of this study, it was suggested that we should be aware the rare problems of titanium toxicity.
BackgroundRehabilitating severely atrophic alveolar crests remains challenging for implantologists and maxillofacial surgeons. Recently, a combination of augmentation and dental implantation has been used to treat cases with severe bone atrophy in the maxilla and mandible. Among autogenous bone grafts, iliac bone grafting (IBG) is considered safe for collecting large amounts of bone and obtaining high-density multipotent cells. However, vertical bone resorption may occur during the initial healing stage after IBG. The purpose of the present study is to evaluate bone graft success and implant survival rate, along with bone height in the augmented site and marginal bone level around dental implants placed in iliac onlay bone grafts. We also introduce technique and treatment considerations for successful IBG procedures, as well as optimal implant installation strategy and soft tissue manipulation.MethodsWe examined seven patients who were treated with IBG combined with implant systems over a period of 10 years. The long-term success rate of bone grafts and implant survival rate were recorded. Bone height change and marginal bone loss (MBL) were analyzed by assessing the radiograms acquired after augmentation, at implant installation, prosthetic loading, and after installation 1 year, 2 years, 3 years, and 5 years.ResultsIn a mean observation period of 50 months (range 12–62 months), the success rate of IBG was 100%. A total of 29 implants were installed and the implant success rate was 100%. The mean bone height reductions compared to post-augmentation bone heights were 1.33 ± 0.81 mm after 3 months, 2.00 ± 1.88 mm at implant installation, 2.55 ± 1.68 mm at prosthetic loading, and 3.05 ± 1.63 mm after implant installation 1 year. The cumulative bone height change after implant installation 5 years was 4.05 ± 1.83 mm which corresponds to a mean resorption rate of 42.5%. The mean MBL after installation 3 months, at prosthetic loading, and after installation 1 year, 2 years, 3 years, and 5 years follow-ups were significantly higher than at implant installation. However, MBL at 2 years, 3 years, and 5 years post-installation did not differ significantly (p < 0.05).ConclusionIn patients with atrophic jaws, a combination of the iliac onlay bone graft and dental implants can result in satisfactory reconstruction and reliable long-term prognosis. Despite early stage vertical bone resorption, we observed high success rates and comparable MBL over long-term follow-up. To reduce bone resorption, case evaluation and surgical planning must be meticulous. Further large-scale studies with longer-term follow-up are needed.
ObjectivesDental implants shorter than 8 mm, called short dental implants (SDIs), have been considered to have a lower success rate than standard length implants. But recent studies have shown that SDIs have a comparable success rate, and implant diameter was more important for implant survival than implant length. Also, SDIs have many advantages, such as no need for sinus lifting or vertical bone grafting, which may limit use in medically compromised patients.Materials and MethodsIn this study, 33 patients with 47 implants 7-mm long were examined over the last four years. All patients had special medical history and were categorized into 3 groups: systemic disorders, such as diabetes mellitus (controlled or uncontrolled), mental disability, and uncontrolled hypertension; oral cancer ablation with reconstruction, with or without radiotherapy; diverse osteomyelitis, such as osteoradionecrosis and bisphosphonate-related osteonecrosis of the jaw. Most of these patients have insufficient residual bone quality due to mandible atrophy or sinus pneumatization.ResultsThe implant diameters were 4.0 (n=38), 4.5 (n=8), and 5.0 mm (n=1). Among the 47 implants placed, 2 implants failed before the last follow-up. The survival rate of 7-mm SDIs was 95.74% from stage I surgery to the last follow-up. Survival rates did not differ according to implant diameter. The mean marginal bone loss (MBL) at 3 months, 1 and 2 years was significantly higher than at implant installation, and the MBL at 1 year was also significantly higher than at 3 months. MBL at 1 and 2 years did not differ significantly.ConclusionWithin the limitations of the present study, the results indicate that SDIs provide a reliable treatment, especially for medically compromised patients, to avoid sinus lifting or vertical bone grafting. Further, long-term follow-up is needed.
accuracy is related to the width (74.7%) of the FM. 31 In Uthman's study, the posterior anterior (length) diameter has the highest accuracy and is contrary to our study.In this study, the results based on Table 4 showed that the age was not correctly determined based on the morphometric analysis of the FM. However, with precise examination in different age groups, it can be concluded that the length and index of FM have a significant relationship with age. But there is no significant relationship between the two.We assume that even this restricted data on FM might be valuable for future examination. The outcome of this study suggest that the results of morphometric data of FM are very crucial in determining sex and age. CONCLUSIONSThe morphological analysis of FM did not display significant differences in age and sex of a person in this population. Meanwhile, the morphometric diameter (length, width) and the area of the FM appeared noteworthy significant different between male and female. In general, higher mean measurement of length, breadth, and area of FM were present in males than in females. It is noteworthy in this population that using morphometric analysis of FM, is not possible to correctly guess the age of the person.
In disease diagnostics and health surveillance, the use of saliva has potential because its collection is convenient and noninvasive. Over the past two decades, the development of salivary utilization for the early detection of cancer, especially oral cavity and oropharynx cancer has gained the interest of the researcher and clinician. Until recently, the oral cavity and oropharynx cancers are still having a five-year survival rate of 62%, one of the lowest in all major human cancers. More than 90% of oral cancers are oral squamous cell carcinoma (OSCC). Despite the ease of accessing the oral cavity in clinical examination, most OSCC lesions are not diagnosed in the early stage, which is suggested to be the main cause of the low survival rate. Many studies have been performed and reported more than 100 potential saliva biomarkers for OSCC. However, there are still obstacles in figuring out the reliable OSCC salivary biomarkers and the clinical application of the early diagnosis protocol. The current review article discusses the emerging issues and is hoped to raise awareness of this topic in both researchers and clinicians. We also suggested the potential salivary biomarkers that are reliable, specific, and sensitive for the early detection of OSCC.
Background: It has been 50 years since Brånemark first introduced the concept of osseointegration. Since then, numerous ongoing research, developments, and optimization of implant properties have been conducted. Despite the high survival and success rates of dental implants, failures still occur in a small number of patients that are being rehabilitated by implants. The purpose of this study was to evaluate the survival and success rate of the Stella® implants that incorporate sand-blasted and acid-etched (S&E) surface treatment and tapered body design to confirm their clinical feasibility and benefits after placement. Methods: We reviewed 61 partially and fully edentulous patients who underwent a tapered, S&E surfaced tissuelevel implant placement between May 2013 and February 2016 in the Department of Oral and Maxillofacial Surgery in the Seoul National University Dental Hospital. Patient characteristics and treatment results were collected, and records of dental implants were analyzed clinically and radiologically. Results: A total of 105 implant fixtures were placed in these patients. The mean age at the time of the surgery was 63.7 years with a range of 31 to 88 years. In total, 4.0-mm and 4.5-mm diameter implants were the most frequently used dental implants (40%, 49%) in this study. Implants 8.5 mm in length were predominantly used (60%). Seventy dental implants were placed in the mandible (70%), and only one dental implant was placed in the maxillary anterior region. At the end of the 5-year observation period, the success rate of the Stella® implants was 98.1%. Among the 105 implants placed, 2 were considered to be failures. Summarizing the clinical and radiographic results, the remaining 103 implants were considered successfully integrated. Conclusion: The overall success rate was 98.1%. The tapered, S&E surfaced tissue-level implant system exhibited great performance in a variety of clinical situations including failed implant sites that enabled predictable and successful treatment outcomes. The effectives of a tapered design of tissue level, not a parallel design, are shown in this clinical report.
Background Silicone-based facial prostheses have traditionally been considered difficult to make and require time-consuming fabrication due to their basic liquid characteristics. Methods and results A detailed procedure for creating an ideal silicone orbital prosthesis was developed, including dental implant-supported retention, three-dimensional (3D) orbital scanning with symmetric volume and size measurement based on matching the opposite side, master mold fabrication for convenient pouring of the liquid silicone elastomer, and easy and comfortable management of the prosthesis by the patient. Conclusion A silicone orbital prosthesis could be more easily and conveniently produced using updated surgical skills and modern 3D technology. The combination of 3D scanning with digital reconstruction and an innovative fabrication protocol using a reproducible major mold and multiple prototypes fitting resulted in an accuracy personalized facial prosthesis with accessible cost and short production period.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.