Halcinonide is a high-potency topical glucocorticoid used for skin inflammation treatments that presents toxic systemic effects. A simple and quick analytical method to quantify the amount of halcinonide encapsulated into lipid nanoparticles, such as polymeric lipid-core nanoparticles and solid lipid nanoparticles, was developed and validated regarding the drug's encapsulation efficiency and in vitro permeation. The development and validation of the analytical method were carried out using the high performance liquid chromatography with the UV detection at 239 nm. The validation parameters were specificity, linearity, precision and accuracy, limits of detection and quantitation, and robustness. The method presented an isocratic flow rate of 1.0 mL.min -1 , a mobile phase methanol:water (85:15 v/v), and a retention time of 4.21 min. The method was validated according to international and national regulations. The halcinonide encapsulation efficiency in nanoparticles was greater than 99% and the in vitro drug permeation study showed that less than 9% of the drug permeated through the membrane, indicating a nanoparticle reservoir effect, which can reduce the halcinonide's toxic systemic effects. These studies demonstrated the applicability of the developed and validated analytical method to quantify halcinonide in lipid nanoparticles.Uniterms: Halcinonide/encapsulation efficiency. Halcinonide/quantification. Polymeric lipid-core nanoparticles. Solid lipid nanoparticles. Topical administration. Toxicity. High performance liquid chromatography/method validation.
Objective: A simple high-performace liquid chromatography method was developed and validated to determine 17-β estradiol in poly (ε-caprolactone) nanocapsules.
Methods: The chromatographic conditions were as follows: C18 GL column with a mobile phase of acetonitrile:water (92:8 v/v) at flow rate of 1.5 mL/min with detection at 280 nm. The evaluated parameters were specificity, linearity, limits of detection and quantification, precision, accuracy, and robustness.
Results: The method was specific and linear (r=0.9982). The limits of detection and quantification were 5.78 μg.mL-1 and 17.54 μg.mL-1, respectively. Suitable accurancy and robustness were obtained. The stability assay showed that pH variation occured after 120 days of storage, and no changes were observed regarding the size and polydispersion parameters. The applicability of the method was evaluated by determining the encapsulation efficiency of the E2 nanocapsules after 120 days of storage. The results showed values >99%.
Conclusion: The results demonstrated the applicability of the developed and validated analytical method.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.