Substitution of systemic dexamethasone for perineural dexamethasone during bupivacaine sciatic and ankle blocks had only a minor analgesic enhancing effect. Given recent animal studies showing dexamethasone neurotoxicity, the perineural route for dexamethasone administration requires reevaluation.
Electrical stimulation of pedicle screws and EMG recording in abdominal and leg muscles in sheep provide a reliable indication of pedicle screw position. This technique can be directly applied to human thoracolumbar surgery, but differences in pedicle size would mean that new threshold voltage criteria would need to be established.
Low-volume ultrasound-guided ankle block is associated with a high block success rate after foot surgery; however, compared with a conventional volume (surface landmark) technique, the reduced local anesthetic volume marginally compromises postoperative analgesia during the first 24 hours.
Needle-nerve stimulation has a false negative motor response rate, which may increase needle passes. This prospective, randomised study tested the hypothesis that femoral nerve catheters placed with ultrasound-only guidance could provide comparable postoperative analgesia to those placed using a conventional nerve stimulation endpoint. Patients presenting for major knee surgery to the lead investigator were recruited. Needles introduced for femoral nerve catheter placement were initially guided with 'oblique' out-of-plane ultrasound imaging but were then prospectively randomised to either an ultrasound (n=21) or nerve stimulation (n=24) endpoint. An elastomeric infusion of ropivacaine 0.2% 2 ml/hour with as required hourly 5 ml boluses was continued for >48 hours in hospital and/or in the home. Needle time under the skin and numerical rating pain score during insertion were recorded. Patients were questioned for worst numerical rating pain score, the need for supplementary ropivacaine boluses and tramadol on postoperative days one and two. There was no difference in the worst numerical rating pain score at rest and on movement and the requirement for supplementary ropivacaine boluses or tramadol during the first 48 postoperative hours. The median (quartiles) needle time under the skin was 58 seconds (51 to 76) in the ultrasound group and 120 seconds (95 to 178) in the nerve stimulation group (P=0.001). The median (quartiles) insertion numerical rating pain score was 2 (0 to 2) in the ultrasound group and 4 (2 to 6) in the nerve stimulation group (P=0.014). Femoral nerve catheters placed for major knee surgery using an ultrasound endpoint provided postoperative analgesia comparable to that obtained when using a nerve stimulation endpoint and were associated with a reduction in both needle manipulations and procedure-related pain.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.