Whether borderline hip dysplasia is pathologic remains unclear. In order to evaluate the three-dimensional joint congruity, this study sought to answer the question: are borderline dysplastic hip curvature mismatch and eccentricity between the acetabulum and the femoral head different from dysplastic or control hips three-dimensionally? The 113 hips, categorized as: dysplastic (LCEA � 20˚), 47 hips; borderline (20˚� LCEA < 25˚), 32 hips; and control (25˚� LCEA < 35˚), 34 hips; were evaluated. Three-dimensional (3D) femoral and coxal bone models were reconstructed from CT images. Using a custom-written Visual C++ routine, the femoral head and acetabular radii of curvature, and the femoral head and the acetabular curvature center were calculated. Then the ratio of the acetabular radius to the femoral head radius (3D curvature mismatch ratio), and the distance between the acetabular curvature center and the femoral head center (3D center discrepancy distance) were calculated. These indices were compared statistically among the three groups using Tukey's post hoc test. The mean 3D curvature mismatch ratio in the borderline (1.13 ± 0.05) was smaller than in the dysplasia (1.23 ± 0.08, p < 0.001), and larger than in the control (1.07 ± 0.02, p < 0.001). The mean 3D center discrepancy distance in the borderline (3.2 ± 1.4 mm) was smaller than in the dysplasia (4.8 ± 2.3, p < 0.001) and larger than in the control (1.6 ± 0.7, p < 0.001). These results demonstrated that three-dimensional congruity of the borderline dysplastic hip is impaired, but its incongruity is not as severe as in dysplastic hips. The 3D curvature mismatch ratio and the 3D center discrepancy distance can be valuable signs of joint congruity in patients with borderline dysplasia. However, future studies are necessary to clarify any associations between curvature mismatch and pathogenesis of osteoarthritis in borderline dysplasia.
Background Although the pedicle is routinely used as a surgical fixation site, the pedicle wall bone area fraction (bone area per unit area) and its distribution at the isthmus of the pedicle remain unknown. The bone area fraction at the pedicle isthmus is an important factor contributing to the strength of pedicle screw constructs. This study investigates the lumbar pedicle wall microstructure based on micro-computed tomography. Methods Six fresh-frozen cadaveric lumbar spines were analyzed. Left and right pedicles of each vertebra from L1 to L5 were resected for micro-computed tomography scanning. Data was analyzed with custom-written software to determine regional variation in pedicle wall bone area fraction. The pedicular cross-section was divided into four regions: lateral, medial, cranial, and caudal. The mean bone area fraction values for each region were calculated for all lumbar spine levels. Results The lateral region showed lower bone area fraction than the medial region at all spinal levels. Bone area fraction in the medial region was the highest at all levels except for L4, and the median values were 99.8% (95.9–100%). There were significant differences between the lateral region and the caudal region at L1, L2 and L3, but none at L4 and L5. The bone area fraction in the lateral region was less than 64% at all spinal levels and that in the caudal region was less than 67% at the L4 and L5 levels. Conclusions This study provides initial detailed data on the lumbar pedicle wall microstructure based on micro-computed tomography. These findings may explain why there is a higher incidence of pedicle screw breach in the pedicle lateral and caudal walls.
This study investigated in vivo the three-dimensional distribution of CT attenuation in the lumbar spine pedicle wall measured in Hounsfield Unit (HU). Seventy-five volunteers underwent clinical lumbar spine CT scans. Data was analyzed with custom-written software to determine the regional variation in pedicle wall attenuation values. A cylindrical coordinate system oriented along the pedicle’s long axis was used to calculate the pedicular wall attenuation distribution three-dimensionally and the highest attenuation value was identified. The pedicular cross-section was divided into four quadrants: lateral, medial, cranial, and caudal. The mean HU value for each quadrant was calculated for all lumbar spine levels (L1–5). The pedicle wall attenuation was analyzed by gender, age, spinal levels and anatomical quadrant. The mean HU values of the pedicle wall at L1 and L5 were significantly lower than the values between L2–4 in both genders and in both age groups. Furthermore, the medial quadrant showed higher HU values than the lateral quadrant at all levels and the caudal quadrant showed higher HU values at L1–3 and lower HU values at L4–5 than the cranial quadrant. These findings may explain why there is a higher incidence of pedicle screw breach in the pedicle lateral wall.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.