In real-world applications-to minimize the impact of failures-machinery is often monitored by various sensors. Their role comes down to acquiring data and sending it to a more powerful entity, such as an embedded computer or cloud server. There have been attempts to reduce the computational effort related to data processing in order to use edge computing for predictive maintenance. The aim of this paper is to push the boundaries even further by proposing a novel architecture, in which processing is moved to the sensors themselves thanks to decrease of computational complexity given by the usage of compressed recurrent neural networks. A sensor processes data locally, and then wirelessly sends only a single packet with the probability that the machine is working incorrectly. We show that local processing of the data on ultra-low power wireless sensors gives comparable outcomes in terms of accuracy but much better results in terms of energy consumption that transferring of the raw data. The proposed ultra-low power hardware and firmware architecture makes it possible to use sensors powered by harvested energy while maintaining high confidentiality levels of the failure prediction previously offered by more powerful mains-powered computational platforms.
General hardware architecture of an energy-harvested wireless sensor network node (EH-WSN) can be divided into power, sensing, computing and communication subsystems. Interrelation between these subsystems in combination with constrained energy supply makes design and implementation of EH-WSN a complex and challenging task. Separation of these subsystems into distinct hardware modules simplifies the design process and makes the architecture and software more generic, leading to more flexible solutions. From the other hand, tightly coupling these subsystems gives more room for optimizations at the price of increased complexity of the hardware and software. Additional engineering effort could be justified by a smaller, cheaper hardware, and more energy-efficient a wireless sensor node. The aim of this paper is to push further technical and economical boundaries related to EH-WSN by proposing a novel architecture which-by tightly coupling software and hardware of power, computing, and communication subsystems-allows the wireless sensor node to be powered by a thermoelectric generator working with about 1.5 • C temperature difference while keeping the cost of all electronic components used to build such a node below 9 EUR (in volume).
Abstract:The aim of this research was to assess the content and composition of the pollutants emitted by domestic central heating boilers equipped with an automatic underfeed fuel delivery system for the combustion chamber. The comparative research was conducted. It concerned fuel properties, fl ue gas parameters, contents of dust (fl y ash) and gaseous substances polluting the air in the fl ue gases emitted from a domestic CH boiler burning bituminous coal, pellets from coniferous wood, cereal straw, miscanthus, and sunfl ower husks, coniferous tree bark, and oats and barley grain. The emission factors for dust and gaseous air pollutants were established as they are helpful to assess the contribution of such boilers in the atmospheric air pollution. When assessing the researched boiler, it was found out that despite the development in design and construction, fl ue gases contained fl y ash with a signifi cant EC content, which affected the air quality.
STRESZCZENIEWspółspalanie węgla i stałych odpadów komunalnych jest zjawiskiem społecznym, stanowiącym poważne źró-dło emisji substancji szkodliwych do powietrza. Przeprowadzono badania porównawcze współspalania węgla kamiennego z poszczególnymi frakcjami stałych odpadów komunalnych (m.in. makulatura, PE, PCV) w kotle CO o mocy 18 kW wyposażonym w automatyczny podajnik paliwa. Badania miały na celu porównanie parametrów spalin, zawartości pyłu (popiołu lotnego) i gazowych substancji zanieczyszczających powietrze w emitowanych spalinach z danego kotła CO. Podczas spalania pobierane były próbki emitowanego pyłu oraz analizowany był w sposób ciągły skład jakościowy i ilościowy spalin -analiza chemiczna spalin obejmowała: CO 2 , CO, H 2 O, SO 2 , NO x . Oznaczono ponadto stężenie pyłu w spalinach. Pobrany popiół lotny został poddany oznaczeniom zawartości węgla C -organicznego, elementarnego i całkowitego, PM10 i PM2,5 oraz zawartości 16 WWA. Wyniki zostały przeanalizowane pod względem efektywności spalania, emisji głównych zanieczyszczeń (NO x , CO, SO 2 ) i popiołu lotnego oraz zaadsorbowanych na jego powierzchni WWA. Średnie stężenie emitowanego pyłu wynosiło 764 mg m -3 , natomiast CO -1944, SO 2 -1256, NO x -555 mg m -3 (STP, 3% O 2 , gaz suchy). Spaliny zawierały popiół lotny, ze znaczną zawartością węgla EC (średnio 31%) oraz wysokim udziałem PM10 oraz PM2,5 -odpowiednio 100 i 75% obj.Słowa kluczowe: popiół lotny, odpady stałe, wskaźniki emisji EMISSIONS FROM CO-COMBUSTION OF COAL AND MUNICIPAL SOLID WASTE IN DOMESTIC CENTRAL HEATING BOILERABSTRACT Co-combustion of coal and solid municipal waste is a social phenomenon. It constitutes an important emission source of harmful air pollutants. The comparative research was conducted. It concerned co-combustion of coal and different types of municipal solid waste (including wastepaper, PE, PVC) in the domestic CH (central heating) boiler (18-kW power) equipped with an automatic fuel feeder. The aim of this research was to compare the parameters of flue gas, content of dust (fly ash) and gaseous air pollutants in the flue gases from the CH boiler. During the combustion were taken the fly ash samples and was continuously analyzed qualitative and quantitative composition of flue gas. Chemical analysis of flue gases included: CO 2 , CO, H 2 O, SO 2 and NO x . Concentration of fly ash in the flue gas was determined. The fly ash samples were analysed for the organic, elemental and total carbon, PM10 and PM2,5, and 16 PAHs content. The results were analyzed in terms of combustion efficiency, emissions of major pollutants (NO x , CO, SO 2 ) and fly ash with adsorbed of PAHs on its surface. The average concentration of emitted particulate matter was 764 mg m -3 , and CO -1944, SO 2 -1256 NO x -555 mg m -3 (STP, 3% O 2 , dry gas). The flue gases contain fly ash, with a significant carbon content EC (average 31%) and a high proportion of PM10 and PM2.5 -respectively 100 and 75% by volume.
Abstract.One of the source of air pollutants is emission from local coalfired boiler-houses and domestic heating boilers. The consequence of incineration of municipal waste is the introduction of additional pollutants into the atmosphere, including fly ash. The aim of this work was to evaluate the particle size distribution of fly ash emitted by coal combustion and co-incineration of coal with municipal waste in a domestic 18 kW central heating boiler equipped with an automatic fuel feeder. Mixtures of bituminous coal with different types of solid waste (5, 10 and 15% of mass fraction) were used. Solid waste types consisted of: printed, colored PE caps, fragmented cable trunking, fragmented car gaskets and shredded tires from trucks. During the incineration of a given mixture of municipal waste with bituminous coal, the velocity of exhaust gas was specified, the concentration and mass flow of fly ash were determined together with the physico-chemical parameters of the exhaust gas, the samples of emitted fly ash were taken as the test material. Particle size analysis of fly ash was performed using laser particle sizer Fritch Analysette 22. The PM10 share from all fly ashes from incineration of mixtures was about 100%. Differences were noted between PM2.5 and PM1.
In this study, the effect of the addition of waste on the emissions from coal co-combustion was investigated. Coal was co-combusted with different additions of medium-density fiberboard and polyethylene terephthalate plastic (10 and 50%), in a low-power boiler (18 W). Polycyclic aromatic hydrocarbons, phenols, alkylphenols, phthalates, and biomass burning markers emissions were determined. Gas chromatography, coupled with a mass spectrometry detector, was used to analyze these compounds in particulate matter and gas phase, after extraction and derivatization. The emissions of polycyclic aromatic hydrocarbons were the highest among all the compounds determined. The total emission of these compounds was 215.1 mg/kg for coal, and 637.7 and 948.3 mg/kg for a 10 and 50% additive of polyethylene terephthalate plastic, respectively. For the 10 and 50% additive of medium-density fiberboard, the total emission was 474.2 and 464.0 mg/kg, respectively. The 50% addition of PET also had the highest emissions of phenols (638.5 mg/kg), alkylphenols (246.5 mg/kg), and phthalates (18.1 mg/kg), except for biomass burning markers, where the emissions were the highest for the 50% addition of medium-density fiberboard (541.3 mg/kg). In our opinion, the obtained results are insufficient for the identification of source apportionment from household heating.
Abstract:Coke plants, which produce various types of coke (metallurgical, foundry or heating), at temperatures between 600 and 1200°C, with limited access to oxygen, are major emitters of particulates and gaseous pollutants to air, water and soils. Primarily, the process of wet quenching should be mentioned, as one of the most cumbersome. Atmospheric pollutants include particulates, tar substances, organic pollutants including B(a)P and many others. Pollutants are also formed from the decomposition of water used to quench coke (CO, phenol, HCN, H2S, NH3, cresol) and decomposition of hot coke in the first phase of quenching (CO, H2S, SO2) [1]. The development of the coke oven technology has resulted in the changes made to different types of technological installations, such as the use of baffles in quench towers, the removal of nitrogen oxides by selective NOx reduction, and the introduction of fabric filters for particulates removal. The BAT conclusions for coke plants [2] provide a methodology for the measurement of particulate emission from a wet, low-emission technology using Mohrhauer probes. The conclusions define the emission level for wet quenching process as 25 g/Mgcoke. The conducted research was aimed at verification of the presented method. For two of three quench towers (A and C) the requirements included in the BAT conclusions are not met and emissions amount to 87.34 and 61.35 g/Mgcoke respectively. The lowest particulates emission was recorded on the quench tower B and amounted to 22.5 g/Mgcoke, therefore not exceeding the requirements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.