The paper presents a method of pore connectivity analysis applied to specimens of cement based composites differing in water to cement ratio. The method employed X-ray microtomography (micro-CT). Microtomography supplied digitized three-dimensional radiographs of small concrete specimens. The data derived from the radiographs were applied as an input into the application based on the algorithm called 'random walk simulation'. As the result a parameter called diffusive tortuosity was established and compared with estimated porosity of examined specimens.Keywords: X-ray tomography, concrete microstructure, diffusive tortuosityArtykuł prezentuje metodę wyznaczania parametru charakteryzującego intensywność połączeń mikroporów w zastosowaniu do próbek kompozytów z matrycą cementową, różniących się stosunkiem wodnocementowym. Metoda bazuje na wynikach badań z zastosowaniem mikrotomografii rentgenowskiej. Analizowano zdigitizowane zestawy danych, opisujące trójwymiarową reprezentację mikrostruktury niewielkich próbek wykonanych z betonu. Przygotowane w ten sposób skany mikrostruktury zastosowano jako dane wejściowe wprowadzone do oprogramowania wykorzystujacego algorytm 'przypadkowo migrujących cząstek wirtualnych'. W ten sposób wyznaczono parametr mikrostruktury znany jako krętość dyfuzyjna. Parametr ten porównano z porowatością obserwowaną wyznaczoną dla zbadanych próbek przy wykorzystaniu analizy jasności voxeli w analizowanych próbkach.
Composite materials based on Cu matrix have a wide range of applications because of their extraordinary features such as high thermal conductivity and high mechanical strength. The preparation of Cu-ZrB2 and CuCr1Zr-ZrB2 composites via gas pressure infiltration technology is described in this work. In contrast to most ceramic materials, ZrB2 is electrically and thermally conductive. All tested samples, i.e. prepared from the ZrB2 porous preform with a porosity of 40 % were infiltrated with molten Cu or CuCr1Zr alloy. Microstructure and homogeneity after infiltration were examined by SEM-EDS microscopy. The interface between the Cu matrix and ZrB2 ceramics was explored by TEM microscopy. As-infiltrated composites were thermally cycled up to 800 • C with heating and cooling rates of 3 • C min −1 in an argon atmosphere.
In the paper two advanced methods for testing cement based composites are described and compared. These are X-ray microtomography and optical microscopy. Microtomography supplies three-dimensional images of small concrete specimens. In the tomograms all cracks, pores and other voids and inclusions, that exceed a few micrometers, are shown. Such visualisation can become a valuable tool for analysis of the basic material properties. Images obtained on thin sections and analysed with various methods on optical microscopes supply additional information on material microstructure that cannot be obtained in tomograms. For example it is relatively easy to determine zone penetrated by CO 2 ingress. These two methods, presented on examples of tests, complete each another in order to supply a set of information on composition and defects of tested composite materials.Keywords: cement matrix composites, concrete deterioration, X-ray tomography, microscopic analysis, concrete microstructure W artykule przedstawiono dwie nowoczesne metody analizy struktury materiałów kompozytowych ze spoiwem na bazie cementu. Są to mikrotomografia komputerowa oraz optyczna analiza cienkich szlifów. Mikrotomografia pozwala na uzyskanie trójwymiarowych obrazów niewielkich próbek betonowych. Na tomogramach widoczne są układy rys, porów i innych pustek, których wymiary przekraczają kilka mikrometrów. Przestawienie tych obiektów w przestrzeni jest ważnym narzędziem do analizy podstawowych właściwości materiału. Obrazy uzyskane na cienkich szlifach w mikroskopie optycznym, analizowane następnie różnymi metodami, dostarczają dodatkowych informacji o mikrostrukturze materiału, które nie mogą być dostrzeżone na tomogramach. Stosunkowo łatwo jest np. uzyskać obrazy stref skarbonatyzowanej matrycy cementowej. Obie przedstawione metody uzupełniają się wzajemnie i pozwalają na otrzymanie zbioru informacji o składzie i defektach badanych materiałów kompozytowych.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.