ObjectiveWe aimed to compare the retention characteristics of Essix and Hawley retainers.MethodsAdolescents undergoing fixed appliance treatment at 2 centers were recruited for this study. Twenty-two patients (16 women and 6 men) wore Essix retainers (Essix group) while 20 (14 women and 6 men) wore Hawley retainers (Hawley group). The mean retention time was 1 year, and the mean follow-up recall time for both groups was 2 years. Two qualified dental examiners evaluated the blind patient data. Maxillary and mandibular dental casts and lateral cephalograms were analyzed at 4 stages: pretreatment (T1), post-treatment (T2), post-retention (T3), and follow-up (T4).ResultsThe results revealed that Essix appliances were more efficient in retaining the anterior teeth in the mandible during a 1-year retention period. The irregularity index increased in both arches in both groups after a 2-year post-retention period. The mandibular arch lengths increased during treatment and tended to return to their original value after retention in both groups; however, these changes were statistically significant only in the Hawley group. Cephalometric variables did not show any significant differences.ConclusionsThe retention characteristics of both Essix and Hawley retainers are similar.
The impacted canines caused root resorption of lateral incisors. The angulation of the canine was steeper on the labial side than on the palatal side but root resorption of adjacent laterals was not different. There were no statistically significant differences in the amount of root resorption of the laterals when the canine was evaluated according to localization and angulation.
The effects of the chemical nature of TCMs on the SBS values appeared to be clinically negligible, whereas the type of surface treatments had a significant influence on bond strengths. Er:YAG laser irradiation caused a significant increase in bond strength between the TCMs and orthodontic brackets.
Objectives:The aim of this study was to compare the accuracy, reproducibility, efficacy and effectiveness of measurements obtained using digital models with those obtained using plaster models.Materials and Methods:A total of 20 digital models were produced by the Ortho Three-dimensional Models (O3DM) Laboratory and their software (O3DM version 2) was used to obtain measurements. Identical plaster models were used to obtain measurements of teeth with a vernier caliper. The maximum mesiodistal width of each study model, from first molar to first molar, was measured. All measurements were repeated at least 1 month later by the same operator for both digital and manual methods. The data were analyzed using Cronbach α, Wilcoxon signed rank test and the McNemar test.Results:Cronbach α value of the data at T1 and T2 for 6 anterior and 12 overall teeth measured using the two methods was very close to the ideal value of 1, indicating high intra-observer reliability. The Wilcoxon signed rank test showed statistically significant differences between the two methods (P = 0.000, P < 0.001). The measurements obtained using the digital models were lower than those obtained using the plaster models. No statistically significant differences were found between the two methods for anterior Bolton discrepancies (P = 0.375) or overall Bolton discrepancies (P = 0.00). Paired comparisons of repeated measurements for Bolton ratios showed no statistically significant differences for anterior or overall Bolton discrepancies (P = 0.688 and P = 0.375, respectively).Conclusions:Use of O3DM software is an acceptable alternative to the traditional vernier caliper method in orthodontic practice.
The results of this study emphasize the need for due consideration of psychological parameters before and during treatment with extra-oral appliances, particularly with regard to depression and anxiety.
Er:YAG laser application did not allow for elimination of the hydrofluoric acid step. RelyX U 200 is a viable alternative to Transbond XT on sandblasted porcelain.
Introduction. The aim of this study was to analyze the effects of screw design and force application on the stability of miniscrews, using RTT, SEM, and histomorphometric analyses. Materials and Methods. Eighty cylindrical, self-drilling, and Ti6Al4V alloy miniscrews (1,6 × 6 mm) were used. Four mini-screws were inserted in fibulas of each rabbit, and 115 G of force was immediately applied. Four miniscrews were inserted in the other fibula, on which no force was applied. Eight weeks after insertion, osseointegration between miniscrew and the surrounding bone was evaluated by the histomorphometric analyses, SEM, and RTT. Kruskal-Wallis and the paired t-tests were used for statistical analysis. Results. Values obtained from Group I were significantly higher than those of the other loaded groups (P < .05). There were no differences in RTT scores among Groups II, III, and IV. Similar findings were also observed for unloaded mini-screws. There was no significant difference between Groups I and IC, while the differences between loaded and unloaded controls for each miniscrew were statistically significant. Conclusions. Immediate loading of miniscrews does not impair screw stability. Also, the diameter of miniscrew and more frequent thread pitches have a positive effect on stability; however, length of miniscrews does not have a significant effect on the stability.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.