Background/aim: Sonographic assessment of diaphragm structure and function would be a useful clinical tool in patients with chronic obstructive pulmonary disease (COPD). Our aim was to determine the muscle thickness of the diaphragm and the usefulness of clinical practice in patients with COPD.
Materials and methods:The diaphragmatic thickness of 34 COPD patients and 34 healthy subjects was measured during tidal volume (Tmin) and deep inspiration (Tmax) on both sides using a B-mode ultrasound. The body mass index and the modified Medical Research Council (mMRC) index values were reported.Results: There was no correlation among TminR (P = 0.134), TminL (P = 0.647), TmaxR (P = 0.721), and TmaxL (P = 0.905) between the patients with COPD and the control group. There was also no significant difference between diaphragmatic thickness and COPD severity, respiratory function (P = 0.410), and frequency of exacerbations (P = 0.881) and mMRC (P = 0.667).
Conclusion:Diaphragmatic dysfunction in COPD is related to mobility restriction rather than muscle thickness.
Introduction. Airway management is one of key elements of resuscitation. Endotracheal intubation is still considered the gold standard for airway management during resuscitation. Aim. The aim of the study was to compare success rates and intubation time of different endotracheal intubation methods during emergency intubation with difficult airways in the conditions of cardiopulmonary resuscitation in a standardized manikin model. Methods. The study was designed as a prospective, randomized, cross-over simulation study. It involved 46 paramedics with at least 5 years of experience in Emergency Medical Service. The participants performed endotracheal intubation under difficult airway conditions during continuous chest compression, implemented with the LUCAS3 chest compression system. Three methods of tracheal intubation were applied: (1) standard Macintosh laryngoscope without a bougie stylet; (2) standard laryngoscope and a standard bougie stylet; (3) standard laryngoscope and a new bougie stylet. Results. The overall intubation success rate was 100% in the standard bougie and new bougie groups and lower (86.9%) when no bougie stylet was used (P=0.028). The intubation success rate with the 1st attempt equalled 91.3% for the new bougie group, 73.9% for standard bougie, and only 23.9% in the no-bougie group. The median intubation time was shortest in the new bougie group, where it amounted to 29 s (interquartile range [IQR]: 25–38); the time equalled 38s (IQR:31–44.5) in the standard bougie group and 47.5s (IQR:36–58) in the no-bougie group. The ease of use was lowest in the no-bougie group (85, IQR:63–88), average in the standard bougie group (44, IQR:30–51), and highest in the new bougie stylet group (32, IQR:19–41). Conclusion. In this manikin-based study, paramedics were able to perform endotracheal intubation with higher efficacy and in a shorter time using the new bougie stylet as compared with the standard bougie stylet.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.