UMEC/VI was associated with statistically significant and clinically meaningful improvements in lung function versus TIO. UMEC/VI was well tolerated. UMEC/VI 62.5/25 mcg could provide an effective new treatment option for patients with moderate-to-very severe COPD.
We compared the efficacy and safety of ipratropium bromide/albuterol delivered via Respimat inhaler, a novel propellant-free inhaler, versus chlorofluorocarbon (CFC)-metered dose inhaler (MDI) and ipratropium Respimat inhaler in patients with COPD. This was a multinational, randomized, double-blind, double-dummy, 12-week, parallel-group, active-controlled study. Patients with moderate to severe COPD were randomized to ipratropium bromide/albuterol (20/100mcg) Respimat inhaler, ipratropium bromide/albuterol MDI [36mcg/206mcg (Combivent Inhalation Aerosol MDI)], or ipratropium bromide (20mcg) Respimat inhaler. Each medication was administered four times daily. Serial spirometry was performed over 6h (0.15min, then hourly) on 4 test days. The primary efficacy variable was forced expiratory volume in 1s (FEV(1)) change from test day baseline at 12 weeks. A total of 1209 of 1480 randomized, treated patients completed the study; the majority were male (65%) with a mean age of 64 yrs and a mean screening pre-bronchodilator FEV(1) (percent predicted) of 41%. Ipratropium bromide/albuterol Respimat inhaler had comparable efficacy to ipratropium bromide/albuterol MDI for FEV(1) area under the curve at 0-6h (AUC(0-6)), superior efficacy to ipratropium Respimat inhaler for FEV(1) AUC(0-4) and comparable efficacy to ipratropium Respimat inhaler for FEV(1) AUC(4-6). All active treatments were well tolerated. This study demonstrates that ipratropium bromide/albuterol 20/100mcg inhaler administered four times daily for 12 weeks had equivalent bronchodilator efficacy and comparable safety to ipratropium bromide/albuterol 36mcg/206mcg MDI, and significantly improved lung function compared with the mono-component ipratropium bromide 20 mcg Respimat inhaler. [Clinical Trial Identifier Number: NCT00400153].
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.