Here we introduce a new concept for x-ray computed tomography that yields information about the local micro-morphology and its orientation in each voxel of the reconstructed 3D tomogram. Contrary to conventional x-ray CT, which only reconstructs a single scalar value for each point in the 3D image, our approach provides a full scattering tensor with multiple independent structural parameters in each volume element. In the application example shown in this study, we highlight that our method can visualize sub-pixel fiber orientations in a carbon composite sample, hence demonstrating its value for non-destructive testing applications. Moreover, as the method is based on the use of a conventional x-ray tube, we believe that it will also have a great impact in the wider range of material science investigations and in future medical diagnostics.
The understanding of large biophysical systems at the systems level often depends on a precise knowledge of their microstructure. This is difficult to obtain, especially in vivo, because most imaging methods are either limited in terms of achievable field of view, or make use of penetrating ionizing radiations such as x-rays, in which case the resolution is severely limited by the deposited dose. Here, we describe a new method, x-ray vector radiography (XVR), which yields various types of information about the local orientation, anisotropy and average size of the sample microstructures. We demonstrate the feasibility by showing first experimental XVRs of human vertebra bone samples, giving information on the trabecular structures even with a pixel resolution of half a millimetre, much larger than the structures themselves. This last point is critical for the development of low-dose measurement methods which will allow for in vivo studies and potentially in the future for new medical diagnostics methods of bone metabolic disorder diseases such as osteoporosis.
X-ray imaging using a Talbot-Lau interferometer, consisting of three binary gratings, is a well-established approach to acquire x-ray phase-contrast and dark-field images with a polychromatic source. However, challenges in the production of high aspect ratio gratings limit the construction of a compact setup for high x-ray energies. In this study we consider the use of phase gratings with triangular-shaped structures in an x-ray interferometer and show that such gratings can yield high visibilities for significantly shorter propagation distances than conventional gratings with binary structures. The findings are supported by simulation and experimental results for both cases of a monochromatic and a polychromatic source.
X-ray dark-field scatter imaging allows to gain information on the average local direction and anisotropy of micro-structural features in a sample well below the actual detector resolution. For thin samples the morphological interpretation of the signal is straight forward, provided that only one average orientation of sub-pixel features is present in the specimen. For thick samples, however, where the x-ray beam may pass structures of many different orientations and dimensions, this simple assumption in general does not hold and a quantitative description of the resulting directional dark-field signal is required to draw deductions on the morphology. Here we present a description of the signal formation for thick samples with many overlying structures and show its validity in experiment. In contrast to existing experimental work this description follows from theoretical predictions of a numerical study using a Fourier optics approach. One can easily extend this description and perform a quantitative structural analysis of clinical or materials science samples with directional dark-field imaging or even direction-dependent dark-field CT.
We report on an x-ray cone-beam differential phase-contrast computed laminography (DPC-CL) method for tomographic reconstruction of thin and lamellar objects. We describe the specific scan geometry of DPC-CL, which consists of a Talbot-Lau grating interferometer and a lab-based x-ray tube source, and derive a filtered back-projection (FBP) reconstruction algorithm. The experimental results of a flat sphere phantom and a piece of ham demonstrate the validity of the proposed technique. The existing DPC-CL methods are based on synchrotron sources and the parallel-beam geometry. In contrast, our approach adopts a more accessible x-ray tube source and a cone-beam geometry. Therefore it significantly widens the application range of phase-contrast laminography, particularly in practical laboratory settings, beyond applications at large-scale synchrotron facilities.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.